International journal of computer assisted radiology and surgery

Integration of weight-bearing computed tomography and magnetic resonance imaging for advanced musculoskeletal statistical shape modeling of the foot and ankle.

Melissa R Requist, Eliana Moreno, Curran Reddy, Andrew C Peterson, Megan K Mills, Amy L Lenz

Medical Scientist Training Program, University of Utah, 26 S 2000 E, Salt Lake City, UT, 84112, USA. · Department of Mechanical Engineering, University of Utah, 1495 E 100 S, Salt Lake City, UT, 84112, USA.

Key points

From the paper's conclusion
  • This method allows for application of shape modeling to novel questions in musculoskeletal morphology through simultaneous modeling of bone and soft tissue anatomy. Limitations include manual registration and MRI resolution. This analysis presented examples of muscle and growth plate models, but has broader applications in musculoskeletal analysis.

Abstract

PURPOSE: Statistical shape models (SSMs) from three-dimensional (3D) medical imaging describe morphology variation in normal and pathologic anatomy. Within the foot and ankle, weight-bearing computed tomography (WBCT) is used to characterize skeletal deformity but poorly visualizes soft tissue. Magnetic resonance imaging (MRI) provides improved evaluation of soft tissue structures but less accurate bone visualization. This methodologic analysis describes and tests reliability of a novel process to generate SSMs from coregistered MRI and WBCT structures. This method is illustrated via two example models: a combined musculoskeletal model and a distal tibia growth plate model. METHODS: Bilateral WBCTs and T1-weighted DIXON MRIs of the lower legs were collected from 14 individuals aged 8 to 18 with no prior lower limb surgery in a control group and hereditary neuropathy group. Bones were segmented from WBCT and manually aligned in MRI space. Alignment reliability was evaluated with intraclass correlation coefficients (ICCs). Six muscles were segmented semi-automatically and the distal tibia growth plate was manually segmented from MRI. Following cropping, size normalization, and alignment multi-domain SSMs were generated. SSMs were evaluated qualitatively through comparison with expected anatomy and quantitively by calculation of compactness, generalization, and specificity. RESULTS: The alignment method demonstrated excellent reliability with an intrarater ICC of 1 and interrater ICC of 0.999. The musculoskeletal model demonstrated expected atrophy in neuromuscular disease and the preliminary growth plate model showed variation in metaphyseal thickness. Both models demonstrated compactness, specificity, and generalization comparable to published SSMs, requiring 11 and 12 modes to account for 95% of population variance. CONCLUSION: This method allows for application of shape modeling to novel questions in musculoskeletal morphology through simultaneous modeling of bone and soft tissue anatomy. Limitations include manual registration and MRI resolution. This analysis presented examples of muscle and growth plate models, but has broader applications in musculoskeletal analysis.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Integration of weight-bearing computed tomography and magnetic resonance imaging for advanced musculoskeletal statistical shape modeling of the foot and ankle — Science Skim