bioRxivPreprintOpen accessbioengineering

Reproducible and open-source statistical shape models of the pose-normalized adult lower body: development and comparative evaluation

M. Abdullah, A. A. Hulleck, K. Khalaf, M. El-Rich

Key points

From the paper's conclusion
  • This study developed a reproducible workflow and compared four statistical shape model families of the pose-normalized adult lower body: pooled global, articulated shape-pose, sex-conditioned shared-basis, and independently fitted sex-specific models.

Abstract

Accurate skeletal geometry is important for subject-specific musculoskeletal modeling, but the choice of statistical representation may affect anatomical reconstruction. This study developed a reproducible workflow and compared four statistical shape model families of the pose-normalized adult lower body: pooled global, articulated shape-pose, sex-conditioned shared-basis, and independently fitted sex-specific models. Models were developed from computed-tomography-derived geometries of 20 adults and evaluated using leave-one-subject-out cross-validation. Model coefficients were estimated from each held-out subjects complete registered surfaces, assessing dense-surface representational generalization. Outcomes included model compactness, whole-body and bone-wise surface root-mean-square errors, and reconstruction errors for hip, knee, and ankle joint centers. A pelvis-referenced bounding-box anisotropic-scaling baseline was included as a geometric comparator. The pooled global and sex-conditioned models shared a principal-component basis and therefore identical compactness spectra, with the first component explaining 90.16% of the variance. These models provided the most consistent reconstruction performance. The articulated model had ankle and knee joint-center errors 9.1 and 5.4 mm higher, respectively, than the pooled global model. Independently fitted sex-specific models did not improve whole-body reconstruction over the pooled global or sex-conditioned models in this small cohort. Under the present evaluation, the pooled global and sex-conditioned models reduced whole-body surface errors by approximately 4.1 and 4.0 mm, respectively, relative to scaling. The pooled global model also reduced ankle and knee joint-center errors by 12.5 and 11.0 mm. These results characterize the implemented representations within the available dataset. The scaling comparison was not input matched, and sparse-input and external validation remain necessary. The accompanying LowerBodySSM workflow and interactive Companion provide a reproducible resource for further anatomical modeling and evaluation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Reproducible and open-source statistical shape models of the pose-normalized adult lower body: development and comparative evaluation — Science Skim