La Radiologia medica

Contrast-enhanced magnetic resonance neurography aids in diagnosis and grading of carpal tunnel syndrome: a preliminary study.

Youzhi Wang, Tingting Liu, Wenjun Wu, Chungao Li, Jie Zhao, Jiamin Kang, Yuxiong Weng, Chuansheng Zheng,

Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, No. 1277 Jiefang Avenue, Wuhan, 430022, China. · Department of Radiology, Wuhan NO.1 Hospital, Wuhan, 430033, China.

Key points

From the paper's conclusion
  • The "negative enhancement" sign on CE-MRN improves the diagnostic accuracy of idiopathic CTS. CE-MRN, which is characterized by three-dimensional visualization, may offer an innovative and non-invasive visual approach for the clinical diagnosis and evaluation of CTS.

Abstract

OBJECTIVES: To preliminarily investigate the diagnostic performance of contrast-enhanced magnetic resonance neurography (CE-MRN) for carpal tunnel syndrome (CTS) and evaluate the association between CE-MRN parameters and clinical assessments. MATERIALS AND METHODS: The study involved thirty-one idiopathic CTS patients and thirty healthy controls. Clinical assessments encompassed symptom evaluation and the Boston Carpal Tunnel Questionnaire (BCTQ). On CE-MRN, a "negative enhancement" sign, defined as focal signal reduction in the median nerve, was used to identify entrapment. Median nerve width and nerve-to-muscle T2 signal intensity ratio (nT2) were measured on CE-MRN and non-contrast MRN (ncMRN), and entrapment length was measured on CE-MRN. Routine MRI metrics encompassed cross-sectional area, flattening ratio, bowing ratio, and relative signal intensity. Diagnostic performance and correlations with clinical variables were analyzed. RESULTS: The CE-MRN demonstrated a sensitivity of 0.87 and specificity of 0.90 for detecting CTS using "negative enhancement" sign. The combination of nerve width and nT2 on CE-MRN, demonstrated higher diagnostic efficacy for CTS compared to routine MRI and ncMRN (AUC 0.87-0.94 for CE-MRN vs. AUC 0.73-0.91 for ncMRN vs. AUC 0.55-0.86 for routine MRI). Among the CE-MRN metrics, nT2 showed a negative correlation with BCTQ symptom scores, while entrapment length demonstrated a positive correlation with disease duration (p < 0.05). CONCLUSIONS: The "negative enhancement" sign on CE-MRN improves the diagnostic accuracy of idiopathic CTS. CE-MRN, which is characterized by three-dimensional visualization, may offer an innovative and non-invasive visual approach for the clinical diagnosis and evaluation of CTS.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers