RDB CycleGAN-CBAM: an integrated deep learning model for low-dose ct image denoising.
Osman Assaf, Albert Güveniş
Institute of Biomedical Engineering, Boğaziçi University, Kandilli, Rasathane Cd. No:104 D:7, 34684 Üsküdar, Istanbul, Turkey. osman.assaf@std.bogazici.edu.tr. · Institute of Biomedical Engineering, Boğaziçi University, Kandilli, Rasathane Cd. No:104 D:7, 34684 Üsküdar, Istanbul, Turkey.
Key points
From the paper's conclusion- These findings support further investigation of RDBCycleGAN-CBAM as a vendor-neutral image-domain denoising approach, while external validation and reader studies are required to establish its clinical utility and potential for dose reduction.
Abstract
Computed Tomography (CT) is one of the largest contributors to radiation exposure from medical imaging, which can induce DNA damage and increase cancer risk. Reducing CT radiation dose to improve patient safety inherently increases image noise and artifacts. Generative adversarial networks (GANs) have shown promise for unsupervised low-dose CT (LDCT) denoising. Building on this, RDBCycleGAN-CBAM, a CycleGAN-based model that integrates residual dense blocks (RDBs) and convolutional block attention modules (CBAM), was developed to effectively denoise quarter-dose CT images while preserving structural detail. The model was trained on unpaired quarter-dose and full-dose CT scans from the NIH-AAPM-Mayo dataset using adversarial (LSGAN), cycle-consistency, and identity losses. Evaluation on held-out test slices was performed using PSNR and SSIM as the primary image-quality metrics. The results demonstrate that the proposed RDBCycleGAN-CBAM method demonstrated improvements that were competitive with values reported in previous studies, achieving mean improvements of + 3.973 dB in PSNR and + 0.053 in SSIM relative to quarter-dose inputs. Shapiro-Wilk tests for PSNR and SSIM motivated the use of the nonparametric Wilcoxon signed-rank test, by which highly significant improvements across both metrics (PSNR and SSIM) were demonstrated. The very large rank-biserial correlation values (1.0) indicate that nearly all test images experienced substantial quality improvement. Furthermore, the narrow bootstrap confidence intervals for the mean differences suggest that these improvements are consistent across the dataset. These findings support further investigation of RDBCycleGAN-CBAM as a vendor-neutral image-domain denoising approach, while external validation and reader studies are required to establish its clinical utility and potential for dose reduction.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Image-Domain GAN Denoising for Sn100 kVp Ultra-Low-Dose Chest CT: A Retrospective Paired Image-Quality Study.Diagnostics (Basel, Switzerland) · 2026
- A multi-scale cross aggregation network for joint denoising and super-resolution of low-dose CT imagesFrontiers in Medicine · 2026
- CycleGAN for Kernel-to-Kernel CT harmonization and low-dose CT denoising via transfer learning.Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2026
- CSRCT: Generalized sparse regularization and convolutional sparse representation for low-dose CT reconstruction.Journal of X-ray science and technology · 2026
- Enhancing low-dose CT denoising via multi-view knowledge transfer without paired dataFrontiers in Radiology · 2026
- Dual-state adaptive unrolled network for structure-preserving low-dose CT image restoration.Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society · 2026