Metabolomics : Official journal of the Metabolomic Society

An approach towards standardized tissue homogenization in metabolomics for improved reproducibility, accuracy and comparability.

Shobhit Madan, Yuntao Hao, Jeannie Horak, Berthold Koletzko

Department of Pediatrics, Dr. Von Hauner Children's Hospital, LMU University Hospital, LMU Medizin, LMU Munich, Lindwurmstrasse 4, 80337 , Munich, Germany. · Department of Pediatrics, Dr. Von Hauner Children's Hospital, LMU University Hospital, LMU Medizin, LMU Munich, Lindwurmstrasse 4, 80337 , Munich, Germany. Jeannie.Horak@med.uni-muenchen.de.

Key points

From the paper's conclusion
  • This study highlights the importance of employing identical TW-to-HS ratios throughout a study, standardizing the description of tissue homogenization experiments by stating the TW-to-HS ratio together with their respective units and the calculated THV used. These are critical determinants for obtaining high reproducibility, accuracy and comparability in tissue metabolomics, especially in clinical areas involving tissue research.

Abstract

INTRODUCTION: Tissue metabolomics enables comprehensive characterization of metabolic processes, but its application is limited by variability introduced during sample collection, storage, homogenization, extraction, and quantification. Standardization of such factors is therefore critical to ensure reproducible and comparable datasets for intra-study data processing and inter-study data merging and comparison. OBJECTIVES: This study presents an optimized and standardized workflow for robust metabolite extraction from pork muscle tissue for targeted mass spectrometry, systematically evaluating key parameters affecting metabolite yield to identify conditions that maximize yield, reproducibility and metabolite class coverage. METHODS: The workflow integrates bead-based tissue homogenization with a two-step metabolite and lipid extraction protocol. Specifically, the impact of (i) tissue weight (TW) to homogenization solution (HS) volume ratios, (ii) different homogenate extract (HX) volumes and (iii) total homogenate volume (THV) on metabolite extraction performance is discussed. Based on metabolite class coverage, optimal conditions are identified. RESULTS: A TW-to-HS ratio of 1:12 and a HX volume of 25 µL provided better and more reproducible results. Under these standardized conditions, more than 350 metabolites were consistently quantified, spanning a wide range of chemical classes, including polar, semi-polar and non-polar species. CONCLUSION: This study highlights the importance of employing identical TW-to-HS ratios throughout a study, standardizing the description of tissue homogenization experiments by stating the TW-to-HS ratio together with their respective units and the calculated THV used. These are critical determinants for obtaining high reproducibility, accuracy and comparability in tissue metabolomics, especially in clinical areas involving tissue research.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers