Redefining reference materials for the evolving metabolomics landscape.
Tracey B Schock, Fabio Casu, Ashley S P Boggs, Amanda L Bayless, Hariharan Iyer, Kristine Gierz, W Clay Davis
Chemical Science Division, National Institute of Standards and Technology, 331 Ft. Johnson Road, Charleston, SC, 29412, USA. tracey.schock@nist.gov. · Chemical Science Division, National Institute of Standards and Technology, 331 Ft. Johnson Road, Charleston, SC, 29412, USA.
Key points
From the paper's conclusion- Here, we introduce the transition toward matrix-specific QC Suites featuring phenotypically distinct metabolite profiles, the first generation of which includes a human plasma suite, urine suite, liver suite, and fecal material.
Abstract
The evolution of metabolomics, a field aimed at comprehensively measuring the small organic molecule composition of a biological matrix, fundamentally reshaped the landscape of analytical measurement reliability. The 2011 release of Standard Reference Material (SRM) 1950 Metabolites in Frozen Human Plasma by the National Institute of Standards and Technology (NIST) marked the first reference material providing certification for 45 analytes to address the measurement precision of complex biological matrices. Assigning high-order values to many compounds is highly resource-intensive for a National Metrology Institute. Furthermore, certified values for individual metabolites cannot resolve the broad challenges associated with sample processing, analytical measurement, and data processing in untargeted workflows. The metabolomics community recognized the potential for SRM 1950 to serve as a benchmark material for method development and technical quality control (QC) rather than strictly for quantification. Recognizing this consumer-driven shift, NIST launched a novel reference material (RM) development strategy to provide accessible, fit-for-purpose materials evaluated by a new statistical framework for production homogeneity, the Coefficient of Disagreement. Here, we introduce the transition toward matrix-specific QC Suites featuring phenotypically distinct metabolite profiles, the first generation of which includes a human plasma suite, urine suite, liver suite, and fecal material. By prioritizing efficient production and embracing a community engagement model for consensus-based deep characterization, these suites offer a reliable tool for laboratory comparisons, instrument assessment, software development, and training. This new class of RMs underpins the next phase of measurement reliability, complementing traditional measurand certification while supporting the diverse needs of comprehensive metabolic profiling.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Standard Reference Material (SRM®) 1950 metabolites in frozen human plasma-use, impact, lessons learned, and future perspectives.Analytical and bioanalytical chemistry · 2026
- A-194 Development of candidate Standard Reference Material® 1950a Metabolites in Frozen Human PlasmaClinical Chemistry · 2026
- MRM Processor: An Integrated Workflow for Automated MRM Data Processing via Relative Retention Time Correction.Analytical chemistry · 2026
- Detecting and Quantifying Variability in Mass Spectrometry-Based Metabolomics Datasets.Biomolecules · 2026
- Normalization of GC-MS Metabolomics Data in Adherent Cells: A Practical Comparison of ApproachesInternational Journal of Molecular Sciences · 2026
- System Performance Check (SPC): A Readiness Companion to Multi-Attribute Method (MAM) Analysis in Biopharmaceutical Quality Control.Pharmaceuticals (Basel, Switzerland) · 2026