Nationwide registry-based automated dose monitoring for dental CBCT: a feasibility study.
Gyu-Dong Jo, Jung Su Kim, Ah-Young Kwon, Ji Yun Lee, Yoon Joo Choi, Kug Jin Jeon, Sang-Sun Han, Chena Lee
Department of Oral and Maxillofacial Radiology, Seoul National University Dental Hospital, 101 Daehak-ro, 03080, Seoul, Korea. · Department of Radiological Technology, Daegu Health College, 5 Yeongsong-ro, 41453, Daegu, Korea.
Key points
From the paper's conclusion- This study demonstrates that nationwide, registry-based monitoring of dental CBCT doses is feasible using routine DICOM data. While providing initial large-scale dose reference estimates, future efforts must focus on external validation, standardized metadata reporting, and tailored classification strategies to establish robust, longitudinal dose surveillance and optimization.
Abstract
OBJECTIVES: To develop and evaluate the feasibilityof a nationwide registry-based automated dose monitoring system for dental cone-beam computed tomography (CBCT). METHODS: A CBCT dose monitoring system was developed to automatically extract dose-related parameters from Digital Imaging and Communications in Medicine (DICOM) headers. The system was implemented at participating dental institutions across the Republic of Korea, and data were collected from CBCT examinations performed between March and November 2025. Device-reported dose-area product (DAP) values were categorized according to field-of-view (FOV) size, patient age group, and institution type. Category-specific DAP distributions were summarized using the minimum, 25th percentile, median, 75th percentile, and maximum values. RESULTS: A total of 22,781 CBCT examinations from 120 participating dental institutions were included. Medium FOV examinations were the most common (21,390; 93.9%), followed by small FOV (1,338; 5.9%) and large FOV examinations (53; 0.2%). The 75th percentile DAP values were 1,898, 2,089, and 1,045 mGy·cm² for large, medium, and small FOV examinations, respectively. Age-specific and institution-type-specific DAP distributions were also generated. Pediatric examinations showed lower 75th percentile DAP values than adult examinations across FOV categories, whereas university hospitals showed higher values than clinics. CONCLUSIONS: This study demonstrates that nationwide, registry-based monitoring of dental CBCT doses is feasible using routine DICOM data. While providing initial large-scale dose reference estimates, future efforts must focus on external validation, standardized metadata reporting, and tailored classification strategies to establish robust, longitudinal dose surveillance and optimization.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Diagnostic Reference Levels for Dental Cone Beam Computed Tomography: A Critical Appraisal of Global Progress and Remaining Gaps.Cureus · 2026
- Toward Indication-Stratified Local Reference Levels for IGRT Cone-Beam CT: A Clinical Audit of CTDIvol and DLP Across Ten Workflows on Versa HD.Health physics · 2026
- Comparative Diagnostic Performance of Cone Beam Computed Tomography and Dual‐Energy X‐Ray Absorptiometry for Low Bone Density Assessment. A Systematic Review and Meta‐AnalysisClinical and Experimental Dental Research · 2026
- Dental Imaging Utilization, Cumulative Exposure and Radiation Dose Patterns in CBCT-Referred Children and Adolescents: A Retrospective Audit.Dentistry journal · 2026
- Clinical rationale and indications for the use of cone-beam computed tomography.BMC oral health · 2026
- Radiation Dose Assessment in Routine Adult Computed Tomography Examinations: A Multi-center Retrospective Study.Health physics · 2026