Intraoperative monitoring of myocardial oxygenation during open-heart surgery: feasibility and initial performance.
Peter Raivio, Liisa Petäjä, Anu Granvik, Tiina Ojala, Erika Wilkman, Mikko Jormalainen, Henri Haapanen, Mikko Lax,
Department of Cardiac Surgery, Heart and Lung Center, Helsinki University Hospital and University of Helsinki, Helsinki, Finland. · Department of Anesthesiology, Heart and Lung Center, Helsinki University Hospital and University of Helsinki, Helsinki, Finland.
Key points
From the paper's conclusion- Real‑time monitoring of ischemia-reperfusion and cardioplegia effects may support intraoperative decision‑making for myocardial protection.
Abstract
Myocardial protection during cardiopulmonary bypass relies on intermittent administrations of cardioplegia without continuous, tissue‑level feedback on myocardial oxygen supply and mitochondrial metabolic status. Extended near‑infrared spectroscopy (eNIRS) can enable real-time intramyocardial monitoring of hemoglobin/myoglobin oxygen saturation (SHb/Mb) and cytochrome c oxidase oxidation (OCcO) for assessment of cardiac oxygen availability and utilization during surgery. In this prospective, single-center feasibility study, myocardial eNIRS monitoring was carried out in 15 adults undergoing aortic valve replacement with or without coronary artery bypass grafting. The study focused on initial feasibility and performance. Clinical performance was explored by relating changes in OCcO responses to intermittently administered blood cardioplegia volumes. Myocardial eNIRS consistently recorded SHb/Mb, and OCcO responses to cross-clamp, cardioplegia, and reperfusion throughout all operations. Mitochondrial oxygenation status improvement (OCcO area under the curve) correlated with the intermittently administered volume of blood cardioplegia (r = 0.68, p < 0.0001). No device-related adverse events were observed. Feedback on usability was favorable (surgeons 87%; anesthesiologists 85%; nurses 74%). Intraoperative myocardial eNIRS monitoring is feasible. It provides continuous assessment of oxygen availability and mitochondrial redox status during surgery. Real‑time monitoring of ischemia-reperfusion and cardioplegia effects may support intraoperative decision‑making for myocardial protection. Clinical trial registration number ClinicalTrials.gov NCT05479968.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Real-time Myocardial Oximetry-Preclinical Monitoring Device Validation in a Porcine Beating-Heart Cardiopulmonary Bypass Model.Annals of thoracic surgery short reports · 2026
- Cerebral Oxygen Saturation Responsiveness During Cardiopulmonary Resuscitation After Prolonged Ventricular Fibrillation: A Porcine Study.Journal of clinical medicine · 2026
- Near-infrared spectroscopy for estimating mixed venous oxygen saturation and cardiac output during off-pump coronary artery bypass grafting: a prospective observational study.Journal of clinical monitoring and computing · 2026
- Continuous Bilateral Lower-Limb Near-Infrared Spectroscopy Monitoring in Patients on Intra-aortic Balloon Pump Support: A Prospective Feasibility and Physiology Study.Journal of cardiothoracic and vascular anesthesia · 2026
- The effect of near-infrared spectroscopy guided intraoperative care on neurocognitive and functional outcomes after cardiac surgery: a systematic review and meta-analysis of randomised controlled trials.British journal of anaesthesia · 2026
- Mitochondrial respiration and nucleotide profiling in human left internal mammary artery from CABG: a novel real-time ex vivo approach.Acta biochimica Polonica · 2026