Consistency and reproducibility of sonographic diagnosis of adenomyosis: an interobserver variability study.
Anastasia Salame, Barbara Lawrenz, Hamidreza Didar, Tatjana Blagojevic, Maryam Farid Mojtahedi, Raquel Del Gallego, Salma Selim, Sara Peralta,
ART Fertility Clinic, Al Ain, United Arab Emirates. · ART Fertility Clinic, Abu Dhabi, United Arab Emirates. barbara.lawrenz@artfertilityclinics.com.
Key points
From the paper's conclusion- Our findings demonstrate only fair interobserver reproducibility for the sonographic assessment of adenomyosis based on the assessment of stored static ultrasound images using the revised MUSA criteria. This degree of variability highlights the challenges associated with consistent interpretation of sonographic features and suggests a need for further refinement and improved standardization of diagnostic approaches.
Abstract
PURPOSE: To study whether there is a marked interobserver discrepancy in the diagnosis of adenomyosis based on reviewing stored sonographic images of infertile patients? METHODS: Three reproductive endocrinology and infertility specialists reviewed stored ultrasound images of 2134 patients attending tertiary IVF-centers. The physicians were blinded to each other as well as to the original diagnosis. The revised Morphological Uterus Sonographic Assessment (MUSA) criteria was used. RESULTS: The overall three-rater agreement for adenomyosis (Yes/No) was 62.3%, with Fleiss' κ = 0.317 (z = 25.4; p < 0.001), indicating fair interobserver reliability. Within cases where all three raters diagnosed adenomyosis (n = 179), interobserver reliability for revised MUSA signs ranged from slight to fair. Overall, even among adenomyosis-positive cases, reproducibility of individual signs varied considerably, with myometrial cysts being the most commonly agreed upon direct feature (K 0.315, 95% CI 0.213-0.412) and asymmetrical myometrial thickening for the indirect features (K 0.406, 95% CI 0.321-0.491). CONCLUSIONS: Our findings demonstrate only fair interobserver reproducibility for the sonographic assessment of adenomyosis based on the assessment of stored static ultrasound images using the revised MUSA criteria. This degree of variability highlights the challenges associated with consistent interpretation of sonographic features and suggests a need for further refinement and improved standardization of diagnostic approaches.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Sonographic Diagnosis of Adenomyosis After the Revised MUSA Consensus: Reproducibility, Predictive Validity and the Case for a Severity ClassificationDiagnostics · 2026
- MRI criteria for adenomyosis: interobserver reproducibility of diagnostic features.Abdominal radiology (New York) · 2026
- The relationship between symptoms of adenomyosis and current ultrasonographic diagnostic criteria.Frontiers in endocrinology · 2026
- Diagnostic accuracy of transvaginal ultrasound for adenomyosis using consensus-based direct and indirect sonographic signs: prospective cohort study.Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology · 2026
- Adenomyosis and association between ultrasonographic features and pregnancy outcomes in women with infertility or pregnancy loss: a systematic review and meta-analysis.EBioMedicine · 2026
- Cumulative Sonographic Features From the Morphological Uterus Sonographic Assessment (MUSA) System and Clinical Severity of Adenomyosis in Congolese Women: A Multicenter Study in Kinshasa, Democratic Republic of the Congo.Cureus · 2026