Abdominal radiology (New York)

MRI criteria for adenomyosis: interobserver reproducibility of diagnostic features.

Ana Villanueva Campos, Elena Canales Lachén, Alba Salgado-Parente, Miguel Ángel Gómez Bermejo, Silvia Gonzalez-Cerron, Irene Pelayo-Delgado

Department of Radiology, HT Medica Hospital Universitario San Rafael, Madrid, Spain. am.villanueva@htmedica.com. · Department of Radiology, Hospital Universitario Ramón y Cajal, Madrid, Spain.

Key points

From the paper's conclusion
  • Reproducibility varied widely across MRI features of adenomyosis, and the intermediate levels of the diagnostic certainty scale were not applied consistently. These findings argue for redefining the current MRI criteria for adenomyosis.

Abstract

PURPOSE: To determine which MRI features used in the diagnosis of adenomyosis are reproducible between readers, and whether a diagnostic certainty scale used in routine reporting can be applied consistently. METHODS: Prospective single-center study of 108 consecutive women referred for 3-T pelvic MRI after transvaginal ultrasound suspicion of adenomyosis. Three subspecialized radiologists, with 10, 8 and 5 years of experience, independently assessed all examinations, blinded to clinical data, ultrasound findings and to each other. Diagnostic certainty was recorded on a four-level ordinal scale (definite, probable, possible, absent). Agreement was quantified with Fleiss' kappa for the three readers, Cohen's kappa for pairs, and weighted kappa for ordinal variables. RESULTS: Agreement for the four-level scale was fair when unweighted (κ = 0.401) and substantial when quadratic-weighted (mean 0.663). No patient was rated probable by all three readers, and agreement across the definite-versus-probable boundary was null (κ = -0.013 to 0.143); collapsing the two categories raised it to κ = 0.581-0.698. For the two direct criteria it was substantial for myometrial hemorrhagic foci (κ = 0.650) and moderate for myometrial cysts (κ = 0.555). Among junctional zone measurements, agreement was moderate for thickness > 12 mm (κ = 0.530) but absent for junctional zone irregularity (κ = 0.048), which was non-evaluable in 21 of 108 examinations (19.4%). These examinations showed a higher prevalence of motion artifacts (p = 0.0005). Agreement on severity grade was moderate (κ = 0.441). CONCLUSION: Reproducibility varied widely across MRI features of adenomyosis, and the intermediate levels of the diagnostic certainty scale were not applied consistently. These findings argue for redefining the current MRI criteria for adenomyosis.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers