Early postoperative objective residual astigmatism after femtosecond LASIK and toric implantable collamer lens implantation: a real-world overlap-weighted stratified comparison.
Yufeng Guo, Ting Zhang
Department of Refractive Surgery, Amass Eye Clinic (Tianhe, Guangzhou), 2nd Floor, No. 161 Linhe West Road, Tianhe District, Guangzhou, 510000, China. 18565217757@163.com. · Department of Refractive Surgery, Amass Eye Clinic (Tianhe, Guangzhou), 2nd Floor, No. 161 Linhe West Road, Tianhe District, Guangzhou, 510000, China.
Key points
From the paper's conclusion- The crude excess of early objective residual astigmatism after TICL was substantially attenuated after balancing measured baseline refractive burden. Within the measured covariate-overlap population, no statistically significant procedure-related difference was observed at M1. These findings suggest that baseline refractive burden materially influenced the crude comparison and do not establish equivalence between procedures.
Abstract
PURPOSE: To compare early postoperative automated-refraction-derived residual cylinder after femtosecond laser-assisted in situ keratomileusis (FS-LASIK) and toric implantable collamer lens (TICL) implantation after balancing measured baseline refractive differences. METHODS: This retrospective real-world cohort used routine clinical records generated between October 2024 and March 2026. The primary endpoint was residual astigmatism greater than 0.50 D at M1, defined as the principal early postoperative analysis point rather than a strictly identical calendar-month visit across procedures. Propensity scores were estimated from age, sex, preoperative spherical equivalent, preoperative cylinder, axis type, and pupil diameter. Overlap weighting was the principal method; robust standard errors were clustered by patient. RESULTS: The final dataset contained 9,218 postoperative records from 3,114 patients and 5,192 eyes. The M1 analysis included 1,059 eyes from 665 patients. TICL eyes had greater baseline refractive burden than FS-LASIK eyes, including higher preoperative cylinder (1.67 vs 1.07 D). Crude analysis suggested higher odds of residual astigmatism after TICL (OR, 2.01; 95% CI, 1.37-2.94; P < 0.001). After overlap weighting, no statistically significant difference was observed in the marginal model (OR, 0.91; 95% CI, 0.57-1.46; P = 0.693) or the covariate-adjusted model (OR, 0.94; 95% CI, 0.59-1.51; P = 0.806). M1 interaction tests did not show statistically significant heterogeneity by cylinder severity or axis type. CONCLUSION: The crude excess of early objective residual astigmatism after TICL was substantially attenuated after balancing measured baseline refractive burden. Within the measured covariate-overlap population, no statistically significant procedure-related difference was observed at M1. These findings suggest that baseline refractive burden materially influenced the crude comparison and do not establish equivalence between procedures.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Short-term comparative outcomes of toric ICL implantation versus femtosecond LASIK for myopic astigmatism.BMC ophthalmology · 2026
- Early Visual Outcomes of Toric Versus Non-Toric IOLs in Low-to-Moderate Corneal Astigmatism: A Real-World Matched Cohort Study.Journal of clinical medicine · 2026
- Astigmatic vector outcomes after FS-LASIK versus SMILE for high myopic astigmatism: a single-center retrospective comparative cohort study without cyclotorsion compensation.International ophthalmology · 2026
- Influence of Astigmatism Magnitude and Axis on the Selection of Non-Toric versus Low-Powered Trifocal Toric Intraocular Lenses in Presbyopic Refractive Lens Exchange.Journal of cataract and refractive surgery · 2026
- Toric versus Standard Implantable Collamer Lens Implantation for Low Myopic Astigmatism: A 12-Month Retrospective Study.Clinical ophthalmology (Auckland, N.Z.) · 2026
- Automated Versus Image-Guided Cyclotorsion Control in FS-LASIK: A Vector Analysis Study.Current eye research · 2026