Effects of SMILE on intraocular pressure and corneal biomechanics: a systematic review and meta-analysis.
Stamatios Lampsas, Gerasimia-Marina Chardalia, Efthymios Karmiris, George D Kymionis, Irini Chatziralli
Second Department of Ophthalmology, School of Medicine, National and Kapodistrian University of Athens, Attikon University Hospital, 1, Rimini Street, 12462, Haidari, Athens, Greece. lampsas.stam@gmail.com. · Second Department of Ophthalmology, School of Medicine, National and Kapodistrian University of Athens, Attikon University Hospital, 1, Rimini Street, 12462, Haidari, Athens, Greece.
Key points
From the paper's conclusion- SMILE leads to significant underestimation of IOP measurements and measurable biomechanical weakening of the cornea. Clinicians should interpret postoperative IOP values cautiously, even when using biomechanically corrected tonometric devices.
Abstract
PURPOSE: Small incision lenticule extraction (SMILE) is a popular flapless refractive procedure for myopia and myopic astigmatism, although postoperative corneal biomechanical changes may affect intraocular pressure measurements and glaucoma assessment. This systematic review and meta-analysis aimed to quantify the postoperative underestimation of IOP and changes in corneal biomechanical parameters following SMILE. MATERIALS AND METHODS: A comprehensive literature search of PubMed, Cochrane Library, ScienceDirect, and Scopus databases was performed up to April 30, 2026, according to PRISMA guidelines. Observational studies reporting preoperative and postoperative IOP measurements after SMILE using Goldmann applanation tonometry (GAT), Ocular Response Analyzer (ORA), or Corvis ST were included. Secondary outcomes included changes in corneal hysteresis (CH) and corneal resistance factor (CRF). RESULTS: Seventeen studies involving 1177 eyes were analyzed. Postoperative IOP was significantly reduced across all tonometric modalities. The pooled mean reduction was greatest with GAT (MD: 3.47 mmHg; 95% CI 2.85-4.10), followed by ORA (MD: 2.50 mmHg; 95% CI 2.06-2.94) and Corvis ST (MD: 1.52 mmHg; 95% CI 0.62-2.42) (all p < 0.001). Significant postoperative reductions were observed in CH (MD: 1.84 mmHg) and CRF (MD: 3.01 mmHg), indicating decreased corneal biomechanical stability after SMILE. CONCLUSIONS: SMILE leads to significant underestimation of IOP measurements and measurable biomechanical weakening of the cornea. Clinicians should interpret postoperative IOP values cautiously, even when using biomechanically corrected tonometric devices.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Anterior segment biometric changes following SMILE surgery and their implications for effective intraocular lens position calculation.International ophthalmology · 2026
- Corneal Biomechanical Metrics by Corvis ST in a Mexican Population: Normative Data and Population-Specific Implications for Intraocular Pressure Assessment.Journal of refractive surgery (Thorofare, N.J. : 1995) · 2026
- Three-Month Ocular Surface and Dry-Eye Outcomes After Implantable Collamer Lens (ICL) Implantation versus Small-Incision Lenticule Extraction (SMILE): A Prospective Non-Randomized Comparative Cohort Study.Clinical ophthalmology (Auckland, N.Z.) · 2026
- Dynamic corneal responses from successive tonometry at different resting intervals using the Corvis ST in young myopesFrontiers in Bioengineering and Biotechnology · 2026
- Factors influencing surgical residual deviation and their impact on higher-order aberrations after SMILE surgery.International ophthalmology · 2026
- Investigating intraocular pressure fluctuations using corneal visualization Scheimpflug technology tonometry (CST) with varied resting intervals.Frontiers in medicine · 2026