Dynamic corneal responses from successive tonometry at different resting intervals using the Corvis ST in young myopes
Xiaoqin Chen, Hongsu Wang, Byung Soo Kang, Xingyi Guo, Lihua Li, Han Yu Zhang, Andrew K. C. Lam
Key points
From the paper's conclusion- Conclusion Corvis ST DCR parameters had only slight changes across successive measurements and different resting intervals from 5 min to no rest in young myopes.
Abstract
Background To investigate the effects of successive measurements and resting intervals on dynamic corneal response (DCR) parameters obtained using corneal visualization Scheimpflug tonometry (Corvis ST). Methods This prospective repeated-measures observational study included young healthy myopes who underwent three successive Corvis ST measurements at four fixed intervals: 5 min (T5m), 2 min (T2m), 30 s (T30s), and immediate succession (Ti). Eleven DCR parameters were analyzed: first applanation time (A1T) and velocity (A1V), deformation amplitude (DA), highest concavity time (HCT), peak distance (PeakDist), deflection amplitude (DefleA), stiffness parameter at first applanation (SP-A1), and stress-strain index (SSI), deflection length at A1 (A1DefLen), deflection amplitude at A1 (A1DefAmp), and deflection area at A1 (A1DefArea). Linear mixed models with a random subject intercept were used to test the effects of successive measurements, intervals, and their interactions, adjusted for axial length (AL), biomechanically corrected intraocular pressure (bIOP), and central corneal thickness (CCT), with Sidak-adjusted post hoc comparisons. Results No interactions between successive measurements and intervals were detected for any parameter (all p > 0.11). Successive measurements significantly affected only DA (p = 0.001). The 2 nd measurement showed a slightly larger DA (+0.010 mm versus the first, p < 0.001). The interval significantly affected the DA (p = 0.005), HCT (p = 0.015), SP-A1 (p = 0.004), A1DefLen (p = 0.005), and A1DefAmp (p = 0.002). The largest adjusted differences were 0.01 mm (DA), 0.09 ms (HCT), 1.5 mmHg/mm (SP-A1), 0.028 mm (A1DefLen), and 0.001 mm (A1DefAmp). A longer AL was independently associated with a larger DefleA (p < 0.001) and PeakDist (p < 0.001). SSI was independent of successive measurements, intervals, bIOP, and CCT (all p > 0.11). Conclusion Corvis ST DCR parameters had only slight changes across successive measurements and different resting intervals from 5 min to no rest in young myopes. Averaging three Corvis ST measurements may be useful, regardless of the resting interval between acquisitions, although further studies are needed.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Investigating intraocular pressure fluctuations using corneal visualization Scheimpflug technology tonometry (CST) with varied resting intervals.Frontiers in medicine · 2026
- Associations between corneal biomechanical parameters and retinal superficial vessel density in young adults with varying myopia severity: a cross-sectional study.Frontiers in medicine · 2026
- Corvis ST Assessment of Corneal Biomechanical Properties in Patients with Type 2 Diabetes Mellitus.Medicina (Kaunas, Lithuania) · 2026
- Corneal Biomechanical Metrics by Corvis ST in a Mexican Population: Normative Data and Population-Specific Implications for Intraocular Pressure Assessment.Journal of refractive surgery (Thorofare, N.J. : 1995) · 2026
- Corneal biomechanical properties and intraocular pressure assessment in pediatric type 1 diabetes mellitus: A comparative Corvis ST study.European journal of ophthalmology · 2026
- Clinical evaluation of corneal elasticity and true IOP using a dual-applanation tonometerFrontiers in Ophthalmology · 2026