Monochromatic Short-Wave UV Sensitivity of Pathogenic Bacteria.
O Yu Manzenyuk, T N Mukhina, M A Kotov, V V Firstova, M R Barkova, V V Kuzin, A N Shemyakin, M Yu Yakimov,
State Research Center for Applied Microbiology and Biotechnology, Federal Service for Surveillance on Consumer Rights Protection and Human Wellbeing, Obolensk, Russia. manzenyuk@obolensk.org. · State Research Center for Applied Microbiology and Biotechnology, Federal Service for Surveillance on Consumer Rights Protection and Human Wellbeing, Obolensk, Russia.
Key points
From the paper's conclusion- The study provides systematic data on the effect of monochromatic UV irradiation across the short-wave range (200‑400 nm) at 17 distinct wavelengths on the viability of pathogenic bacteria.
Abstract
The study provides systematic data on the effect of monochromatic UV irradiation across the short-wave range (200‑400 nm) at 17 distinct wavelengths on the viability of pathogenic bacteria. It was found that each irradiated bacterial species exhibits an individual spectral profile of UV sensitivity. Bacterial viability characteristics were obtained, and UV sensitivity curves were constructed for nine pathogenic bacterial species. Of practical significance is the determination of bactericidal radiation doses required for pathogen inactivation. Furthermore, the constructed spectral UV sensitivity curves allow determining a narrow wavelength range and calculating the mutant-preventing irradiation dose for each pathogen. An individual UV sensitivity profile can be obtained for any unknown cultivable pathogen. The approach is recommended for testing of UV sensitivity of bacterial pathogens, because it enables the use of mild irradiation doses to eliminate both vegetative and persisting cells.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Radiometrically Equivalent Comparison of 254 nm Low-Pressure Mercury Lamps and InGaN 280 nm UV-C LEDs for Surface Disinfection.ACS omega · 2026
- Traceable Measurement of Peak Irradiance and Fluence Rate Enables Accurate Dose Determination of Pulsed Xenon Ultraviolet Disinfection.Environmental science & technology · 2026
- UVC-LED Disinfection Technology: Mainstream Waveband Characteristics, Applications and ChallengesWater Air & Soil Pollution · 2026
- Investigating the Efficacy of Various Photosensitizers and Irradiation Strategies in Antimicrobial Photodynamic Inactivation on Different Types of MicrobesInternational Journal of Molecular Sciences · 2026
- Disinfection and damage of nontuberculous mycobacteria by different UV wavelengthsApplied and Environmental Microbiology · 2026
- Defining Operational UV-C Dose Requirements for Autonomous Disinfection of Clinically Relevant Pathogens Across Healthcare and High-Touch SurfacesbioRxiv · 2026