Mechanical Characterisation of Bone Surrogates: A Systematic Review.
Lauren Gargan, Xiangyun Gao, Michael Bryant, Richard M Hall
School of Engineering, University of Birmingham, Birmingham, UK. lxg409@student.bham.ac.uk. · School of Engineering, University of Birmingham, Birmingham, UK.
Key points
From the paper's conclusion- This systematic review, following the protocol outlined by the PRISMA-2020 methodology, synthesises findings from 88 papers on the mechanical characterisation methods and associated properties of bone surrogates, with results demonstrating significant variations in study design, thus restricting the potential for comparison.
Abstract
Preclinical evaluation of new orthopaedic implants is typically undertaken using cadaveric bone as it provides the most authentic match to the mechanical properties of human bone in vivo. However, the properties of cadaveric bone are highly dependent on physiological factors leading to uncertainty in test results. As an alternative, investigations have been undertaken into the potential suitability of bone surrogates that are capable of replicating bone performance and overcoming some of the complications associated with cadaveric bone, especially in early-stage research. However, these models have been criticised for their performance, which is further impeded by the lack of standardisation in characterising these structures for utilisation in scenario-specific applications. This systematic review, following the protocol outlined by the PRISMA-2020 methodology, synthesises findings from 88 papers on the mechanical characterisation methods and associated properties of bone surrogates, with results demonstrating significant variations in study design, thus restricting the potential for comparison. Due to the hierarchical structure of bone, its mechanical properties are highly influenced by anatomical factors, meaning researchers must ensure surrogate properties align with data from cadaveric bone of the same physiological condition and characterised using an equivalent testing mechanism. Of the studies included in this review, just 23 of 88 characterised the properties of human cadaveric bone alongside the surrogates, with the majority comparing to data from literature obtained using inconsistent loading protocols. Adoption of standards and protocols for production and characterisation of bone surrogates would allow for greater understanding of research gaps that must be addressed prior to replacement of cadaveric bone in orthopaedic research. By consolidating current research, this review aims contribute towards the development of future surrogates capable of representing the complex anatomical and mechanical properties of bone during scenario-specific applications.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Mechanical properties of whole-body human bones: a reviewMaterials Research Express · 2026
- Which Bonding Protocol Provides the Most Durable Zirconia Adhesion after In Vitro Artificial Aging: A Systematic Review.The journal of contemporary dental practice · 2025
- Material and Structural Properties of Adult Human Ribs: A Systematic Review and Test-Condition-Specific Evidence for Thoracic Biofidelity Assessment and Human Surrogate Development.Annals of biomedical engineering · 2026
- Animal models for critical-sized long-bone defects and long-bone non-union: a scoping reviewJournal of Orthopaedic Surgery and Research · 2026
- Progress in multiscale biomechanical assessment of cancellous bone: From bone density to multiscale mechanical phenotypes.Injury · 2026
- Deproteinized Bovine Bone Mineral Enriched with Hyaluronate A comparative Clinical ,Biochemical and Radiographic studyInternational Journal of Drug Delivery Technology · 2026