Annals of biomedical engineering

Smartphone-Based Cuffless Blood Pressure Estimation Using a Multiple Regression Model: Revalidation and On-Demand Performance Under Real-World Conditions.

Takehiro Yamakoshi, Peter Rolfe, Ken-Ichi Yamakoshi

Institute of Liberal Arts and Science, Kanazawa University, Kakuma-machi, Kanazawa, Ishikawa, 920-1192, Japan. takehiroy@me.com. · Department of Automatic Measurement and Control, Harbin Institute of Technology, No.92 West Dazhi Street, Nan Gang District, Harbin, 150001, Heilongjiang Province, China.

Observational · n=11

Key points

From the paper's conclusion
  • The proposed MRM-based method demonstrates practical BP estimation accuracy in daily life. Although further calibration studies are warranted, its long-term stability and smartphone compatibility offer notable advantages for routine BP monitoring. This approach represents a promising, convenient cuffless alternative for integration into mobile healthcare platforms and daily BP management.

Abstract

PURPOSE: Consistent blood pressure (BP) management is crucial for cardiovascular health; yet conventional cuff-based methods remain cumbersome for frequent use. Although cuffless BP technologies are advancing, further validation in daily life is still required. Building on our preliminary work, this study aims to revalidate and further develop a practical, sustainable smartphone-based BP estimation method using multiple regression model (MRM) and assess on-demand performance under real-world conditions. METHODS: Calibration models were constructed using 101 datasets from 13 healthy participants. Target variables were brachial cuff-based systolic and diastolic BP (SBPc/DBPc). Predictor variables reflecting BP regulation were pulse rate index (PRI: ln(PR)) and peripheral vascular resistance index (VRI: |ln(mNPV)|; mNPV: modified normalized pulse volume), derived from smartphone-based fingertip green-light photoplethysmography. Model performance was evaluated by independent validation in additional participants (n = 11) under normal living conditions by comparing estimated BP (SBPe/DBPe) with concurrent cuff-based measurements. RESULTS: Over 1-2 weeks, 168 datasets (13-21 per participant) were collected. Mean absolute errors (MAEs) were 3.2 ± 2.59 mmHg for SBP and 4.7 ± 2.78 mmHg for DBP. A longitudinal case study over 20 months in one participant (752 datasets) demonstrated lower MAEs: 1.6 ± 1.16 mmHg for SBP and 2.4 ± 1.71 mmHg for DBP. CONCLUSION: The proposed MRM-based method demonstrates practical BP estimation accuracy in daily life. Although further calibration studies are warranted, its long-term stability and smartphone compatibility offer notable advantages for routine BP monitoring. This approach represents a promising, convenient cuffless alternative for integration into mobile healthcare platforms and daily BP management.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers