Abdominal Ultrasound Simulation from Semantic Labels Using Paired Label-to-Physics-Based Image Translation.
Santiago Vitale, Duilio Deangeli, Ignacio Larrabide, José Ignacio Orlando
National Scientific and Technical Research Council (CONICET), Godoy Cruz 2290, C1425FQB, Caba, Buenos Aires, Argentina. santiago.vitale@pladema.exa.unicen.edu.ar. · National Scientific and Technical Research Council (CONICET), Godoy Cruz 2290, C1425FQB, Caba, Buenos Aires, Argentina.
Key points
From the paper's conclusion- Training paired generative models with physics-based supervision enables approximation of CT-derived ray-casting outputs at inference time directly from semantic labels. Although the pipeline does not require patient-specific CT volumes at inference time, CT-derived segmentations and ray-casting simulations remain necessary to train Stage I. Once trained, the framework enables controllable healthy and pathological simulations through semantic map modification.
Abstract
PURPOSE: Current abdominal ultrasound (US) simulation methods often require CT-based anatomical references for ray-casting, limiting deformation, and pathology variability. We propose a learning-based pipeline trained to predict physics-based images derived from CT scans from semantic labels, enabling controlled simulations without patient-specific CT volumes at inference time. METHODS: We introduce a two-stage pipeline that maps anatomical segmentations to realistic US images through a simplified US image. Stage I synthesizes this image from semantic labels using models trained on CT-based ray-casting outputs. Stage II refines it into a realistic US scan using anatomically guided unpaired translation. Deformations and pathologies are generated by editing anatomical maps. RESULTS: We evaluated Pix2Pix and the Semantic Diffusion Model (SDM) in Stage I, followed by segmentation-guided CycleGAN (SG-CycleGAN) refinement in Stage II. SDM significantly outperformed Pix2Pix in morphological metrics, including MAE ↓ (19.85 vs. 21.65), SSIM ↑ (0.28 vs. 0.24), and mIoU ↑ (0.43 vs. 0.29), whereas Pix2Pix yielded better perceptual point estimates (LPIPS ↓ : 0.17 vs. 0.19; FID ↓ : 0.32 vs. 0.37; KID ↓ : 0.25 vs. 0.48). CONCLUSION: Training paired generative models with physics-based supervision enables approximation of CT-derived ray-casting outputs at inference time directly from semantic labels. Although the pipeline does not require patient-specific CT volumes at inference time, CT-derived segmentations and ray-casting simulations remain necessary to train Stage I. Once trained, the framework enables controllable healthy and pathological simulations through semantic map modification.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- DiffUS: Differentiable Ultrasound Rendering from Volumetric Imaging.Simplifying medical ultrasound. International Workshop on Advances in Simplifying Medical Ultrasound · 2026
- Beyond Pose Control: Anatomically Consistent Ultrasound Video GenerationarXiv · 2026
- Real-time MRI-ultrasound image translation under limited paired data using a physically motivated conditional GAN.Physics in medicine and biology · 2026
- SonoAtlasWorld: Anatomy-Grounded Ultrasound World Models for Wide-Range ScanningarXiv · 2026
- SonoWorld: Towards Interactive Pose-Controllable Ultrasound World ModelsarXiv · 2026
- Eliminating Registration Bias in Synthetic CT Generation using a physics-based simulation framework for pelvic anatomy.Physics in medicine and biology · 2026