Mechanical Characterization of Fibrin-Based Blood Clot Analogues for Modeling Intracerebral Hemorrhage.
Prabhat Kumar, Adrian Liu, Yigit Can Senol, Daniel Leong, Nanditha Krishnan, Luis E Savastano
Department of Neurological Surgery, University of California, San Francisco, 513 Parnassus Avenue, HSE 860, San Francisco, CA, 94143, USA. prabhat.kumar@ucsf.edu. · Department of Neurological Surgery, University of California, San Francisco, 513 Parnassus Avenue, HSE 860, San Francisco, CA, 94143, USA.
Key points
From the paper's conclusion- Fibrin-based clot analogues provide a reproducible and tunable platform for modeling selected mechanical characteristics of ICH clots. The formulations span distinct mechanical behaviors that may support standardized benchtop and cadaveric evaluation of MIS ICH evacuation technologies.
Abstract
INTRODUCTION: Intracerebral hemorrhage (ICH) carries high mortality and long-term disability. Development of minimally invasive surgical (MIS) evacuation devices is limited by the lack of reproducible clot analogues that reproduce key mechanical features of human ICH clots. This study evaluates the structural and mechanical behavior of engineered clot analogues benchmarked against patient-derived ICH clots. METHODS: Clot analogues were formulated at FFP:pRBC ratios of 85:15, 90:10, and 95:5. Microstructure was qualitatively assessed using scanning electron microscopy (SEM), and mechanical behavior was characterized by strain sweep rheology, flow sweep viscosity, and axial compression. Mechanical properties were benchmarked against three patient-derived ICH specimens. RESULTS: SEM revealed a transition from cell-dominated (85/15) to fibrin-dominant (95/5) microstructures, with 90/10 exhibiting an intermediate architecture. All analogues demonstrated predominantly solid-like behavior (G' > G″), with storage modulus increasing from 334.3 ± 55.0 Pa (85/15) to 499.9 ± 140.5 Pa (95/5) (p = 0.037). Tanδ values overlapped with patient-derived specimens, suggesting similar viscoelastic regimes despite differences in absolute stiffness. Peak viscosity was significantly greater for 85/15 than for 90/10 and 95/5 (p < 0.001). Compressive stress increased numerically with FFP content but did not differ significantly among formulations (p = 0.053). CONCLUSION: Fibrin-based clot analogues provide a reproducible and tunable platform for modeling selected mechanical characteristics of ICH clots. The formulations span distinct mechanical behaviors that may support standardized benchtop and cadaveric evaluation of MIS ICH evacuation technologies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Development and Validation of a Human Cadaveric Model for Lobar Intracerebral Hemorrhage.Neurosurgery practice · 2026
- Arterial shear rate determines the structure and mechanical properties of whole-blood clots.Research and practice in thrombosis and haemostasis · 2026
- Biomaterial thrombosis-on-a-chip: Real-time visualisation of biomaterial thrombosis at clinical heparin levels.Biomaterials · 2026
- A multifunctional injectable hemostatic hydrogel for sustained tranexamic acid delivery and ROS attenuation in intracerebral hemorrhage.Biomaterials advances · 2026
- A Hybrid Hierarchical Framework for Quantifying Mechanical Markers in Atherosclerotic Disease Progression: A New Approach for Diagnosis and Risk Assessment.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
- Multimodal assessment of the skin biomechanical properties during wound healing and hyaluronic acid responsearXiv · 2026