Biomaterials

Biomaterial thrombosis-on-a-chip: Real-time visualisation of biomaterial thrombosis at clinical heparin levels.

Lingzi Gao, Shouyuan Jiang, Tiffany Goh, Jun Ki Hong, Vera M Ripoll, Vivien M Chen, Lining Arnold Ju, Anna Waterhouse

Heart Research Institute, The University of Sydney, 7 Eliza Street, Newtown, NSW, 2042, Australia; Faculty of Medicine and Health, The University of Sydney, NSW, 2006, Australia; The Charles Perkins Centre, The University of Sydney, Camperdown, NSW, 2006, Australia; The University of Sydney Nano Institute, The University of Sydney, Camperdown, NSW, 2006, Australia. · The Charles Perkins Centre, The University of Sydney, Camperdown, NSW, 2006, Australia; The University of Sydney Nano Institute, The University of Sydney, Camperdown, NSW, 2006, Australia; School of Medical Sciences, Faculty of Medicine and Health, The University of Sydney, NSW, 2006, Australia.

Key points

From the paper's conclusion
  • We developed a biomaterial thrombosis-on-a-chip model to evaluate acute material thrombogenicity in real-time using human whole blood, mimicking clinical heparin doses (0.5-5 U/mL) and shear rates (50-2000 s-1).

Abstract

Blood-contacting medical device thrombosis causes device failure, embolism and bleeding due to reliance on anti-thrombotic drugs. The interplay between biological, material and flow parameters in medical device thrombosis remains poorly understood. Importantly, tools to evaluate acute, dynamic thrombotic events on materials in real-time are lacking, impacting the successful development and translation of new anti-thrombotic materials. We developed a biomaterial thrombosis-on-a-chip model to evaluate acute material thrombogenicity in real-time using human whole blood, mimicking clinical heparin doses (0.5-5 U/mL) and shear rates (50-2000 s-1). System validation showed expected platelet adhesion on hydrophilic glass and platelet passivation and detachment at increasing shears on hydrophobic silicone. For the first time, we characterised fibrin events on materials, finding a shear dependent decrease on glass but not silicone, pre-coating materials with albumin abolished fibrin on silicone but not glass, and inhibition of FXIIa reduced but did not abolish fibrin on either material. More and larger fibrin events (aggregation and channel occlusion) occurred at 0.5 U/mL compared to 5 U/mL heparin, and the heparin level did not affect platelet adhesion dynamics. Glass showed the most severe fibrin events, followed by polyvinyl chloride (PVC) > silicone > polycarbonate. Most fibrin events occurred in association with platelets and although platelets were P-selectin positive, very few platelets were procoagulant (P-selectin and Annexin V positive). This clinically relevant, biomaterial thrombosis-on-a-chip model could allow biomaterial thrombosis mechanism elucidation and fast-track evaluation and development of anti-thrombotic materials to improve medical device function and reduce adverse thrombotic and bleeding patient outcomes.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Biomaterial thrombosis-on-a-chip: Real-time visualisation of biomaterial thrombosis at clinical heparin levels — Science Skim