An external reference to enable quantitative susceptibility mapping (QSM) in absolute terms: theoretical considerations, simulations, and experimental evaluation.
Anna Lundberg, Ronnie Wirestam, Jimmy Lätt, Linda Knutsson, Emelie Lind
Department of Medical Radiation Physics, Lund University, Skåne University Hospital, 22185, Lund, Sweden. anna.lundberg@med.lu.se. · Department of Medical Radiation Physics, Lund University, Skåne University Hospital, 22185, Lund, Sweden.
Key points
From the paper's conclusion- Excellent accuracy was demonstrated in the numerical head phantom. Encouraging, although somewhat underestimated, susceptibility results were obtained for the MRI phantom measurements. The relationship between measured and theoretical susceptibility values showed excellent correlation (r = 0.98, p = 0.004). The in vivo measurement yielded an absolute mean susceptibility of 0.02 ppm (relative to water).
Abstract
OBJECTIVE: Quantitative susceptibility mapping (QSM) is a semi-quantitative method, i.e., only differences in magnetic susceptibility can be quantified. The lack of a stable internal reference hampers longitudinal and systematic comparisons among subjects. In this study, a phase-based approach, enabling the use of an external reference, is proposed. MATERIALS AND METHODS: By modeling the object geometry and analyzing the object-induced magnetic field distortion in the external reference, a relationship between the manifested phase and susceptibility was established. The proposed theoretical framework was validated using a numerical head phantom and 3 T MRI measurements, investigating five phantoms with different concentrations of gadolinium and one healthy volunteer. The derived theoretical relationship, together with accurate phase measurements, provided the absolute mean magnetic susceptibility of the object of interest. RESULTS: Excellent accuracy was demonstrated in the numerical head phantom. Encouraging, although somewhat underestimated, susceptibility results were obtained for the MRI phantom measurements. The relationship between measured and theoretical susceptibility values showed excellent correlation (r = 0.98, p = 0.004). The in vivo measurement yielded an absolute mean susceptibility of 0.02 ppm (relative to water). DISCUSSION: Feasibility and proof of concept were demonstrated, and the approach, in combination with conventional QSM, offers an alternative reference solution with potential to facilitate absolute QSM maps.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A geometric anthropomorphic phantom for quantitative susceptibility mapping: accuracy and repeatabilitybioRxiv · 2026
- Magnetic susceptibility source separation technology: a narrative review of principles, validation, and clinical translation.Frontiers in neuroscience · 2026
- Laplace-Mixture Dipole Inversion for Quantitative Susceptibility Mapping.Magnetic resonance in medicine · 2026
- A physics-constrained Bayesian framework for QSM with uncertainty quantification and variational susceptibility source separation.Physics in medicine and biology · 2026
- PI-uMSS: Prior information-based unsupervised magnetic source separation in quantitative susceptibility mappingNeuroImage · 2025
- Susceptibility source separation via Closed-form Alternating Newton-type OptimizationarXiv · 2026