SynPAR for Empirical Membership Inference Auditing of Synthetic Radiomic and Embedding Data.
Clemente García-Hidalgo
Radiology Department, Hospital Universitario Morales Meseguer, Murcia, Spain. clemente292@gmail.com.
Key points
From the paper's conclusion- The findings support assessing discrimination and sensitivity to known exposure jointly at explicitly evaluated operating points when interpreting attack results.
Abstract
To develop and evaluate SynPAR, a framework for reproducible membership-inference auditing and reporting of synthetic radiomic and embedding data. We evaluated feature releases from eight imaging cohorts using distance, density-ratio, and shadow-calibrated attacks. Reference-overlap experiments tested evaluation contamination. Graded exact-copy controls, with separate threshold-calibration and test records, measured discrimination and sensitivity at false-positive-rate (FPR) targets of 1%, 5%, and 10%. Findings informed a seven-item reporting checklist. Reference overlap increased mean density-ratio area under the receiver-operating-characteristic curve (AUC) from 0.502 to 0.809 across five cohorts. Distance-shadow versus shadow-standardized density AUCs were 0.630 versus 0.523 for the conditional variational autoencoder and 0.584 versus 0.521 for the Wasserstein generative adversarial network; both diffusion implementations were near chance under distance-shadow testing. Across 380 controlled release conditions, sensitivity depended on copying fraction and operating point. With complete copying in independent normal-feature experiments, shadow-standardized density achieved AUC 0.967 but sensitivity 0.480 at rank-calibrated target 1% FPR (achieved 1.04%); distance achieved 1.000 for both, with achieved FPR 1.00%. SynPAR links reference checks and measured sensitivity to practical reporting recommendations. The findings support assessing discrimination and sensitivity to known exposure jointly at explicitly evaluated operating points when interpreting attack results.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Evaluating synthetic-data fidelity in two-group biomedical studies: a multidimensional validation frameworkmedRxiv · 2026
- Revisiting TabGraphSyn: training boundaries and record-level conditioning in synthetic clinical data evaluationmedRxiv · 2026
- Diagnostically Meaningful, Privacy-aware Synthetic Chest CT via Class-Conditional Latent Sampling in Diffusion AutoencodersarXiv · 2026
- Detecting Distribution-Based Attribute Inference Risk in Synthetic EHRs.IEEE journal of biomedical and health informatics · 2026
- Auditing a Conditional-VAE Synthetic-Data Firewall for Privacy-Preserving Deep LearningFuture Internet · 2026
- Beyond Fidelity: Evaluating Synthetic Medical Imaging DataarXiv · 2026