Validation of a Deep Learning Model for Automated Ureteral Length Measurement on CT Against Gross Specimens.
Kexin Wang, Zheng Zhao, Yi Liu, Pengsheng Wu, Rile Nai, Xiaochao Guo, He Wang
Department of Radiology, Peking University First Hospital, Beijing, 100034, China. · Department of Urology, Peking University First Hospital, Beijing, 100034, China.
Key points
From the paper's conclusion- The proposed deep learning pipeline achieved accurate fully automated ureteral segmentation and length measurement across diverse CT acquisition phases and demonstrated close agreement with surgical gross specimen measurements in a prospective clinical cohort, supporting its potential to assist preoperative planning and reduce reliance on manual measurement.
Abstract
This study validates a deep learning model for automated ureteral length measurement on CT using gross specimen measurements as the reference standard. A deep learning model was trained on 3629 CT series from 1502 patients (cohort 1) to segment the ureter and extract centerline length. An independent prospective cohort (cohort 2) of 70 patients undergoing radical nephroureterectomy served as the hold-out test set. Each gross specimen was measured twice by one urologist (D1_length and D2_length), with their mean as the reference length (Ref_length). Model-predicted lengths (AI_length) were compared with Ref_length using repeated-measures one-way ANOVA with Tukey post hoc tests. Determinants of discrepancy were assessed with Spearman correlation and multiple linear regression. Marginal means (± SE) were 266 ± 3.85 mm (D1_length), 273 ± 3.25 mm (D2_length), 269 ± 2.75 mm (AI_length), and 269 ± 3.45 mm (Ref_length). Measurement method had a statistically significant but negligible effect on length (F(3, 207) = 2.73, p = 0.045, η2G = 0.007). D1_length and D2_length differed significantly from Ref_length (both p = 0.002), whereas AI_length was not statistically different from Ref_length (p > 0.999). In regression analysis, reference ureteral length was the only independently associated variable (coefficient - 0.54 mm per mm of reference length, 95% CI - 0.70 to - 0.39; p < 0.001); age, sex, body height, body weight, operation side, and lesion location were not significantly associated. The proposed deep learning pipeline achieved accurate fully automated ureteral segmentation and length measurement across diverse CT acquisition phases and demonstrated close agreement with surgical gross specimen measurements in a prospective clinical cohort, supporting its potential to assist preoperative planning and reduce reliance on manual measurement. The measurement discrepancy was governed primarily by ureteral length itself-with a small systematic underestimation in longer ureters-rather than by patient or procedural factors. However, this tendency, together with the single-center design, and the modest size of the prospective cohort, warrants further multicenter validation before routine clinical deployment.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Development and external validation of a machine-learning model for preoperative prediction of impacted ureteral stones in patients undergoing ureteroscopy: a retrospective two-centre studyBMC Medical Informatics and Decision Making · 2026
- Deep learning-based automatic segmentation and quantitative analysis of upper urinary tract stones on non-enhanced CT in stone-positive patients.BMC urology · 2026
- Deep Learning-Based Quantification of Cystoscopic Prostatic Urethral Kissing: Development and Temporal ValidationDiagnostics · 2026
- Automated Structured Pre-Report Generation for Nephrolithiasis on Non-Contrast CT: Development and Report-Level Evaluation of a Deep Learning Framework.Journal of imaging informatics in medicine · 2026
- CT-based clinical deep learning radiomics nomogram for preoperative differentiation of pyelocaliceal upper tract urothelial carcinoma and xanthogranulomatous pyelonephritis.Frontiers in oncology · 2026
- Deep Learning Quality Control for RECIST-Oriented Assessment: A Vision Transformer Predicts Inter-Reader Variability of Unidimensional Lesion Measurements on Contrast CT.Cancers · 2026