Can General-purpose Multimodal AI Reliably Measure Cobb Angles? A Head-to-head Diagnostic Agreement Study of GPT-5.1 and Gemini 3.1 Pro in Adolescent Idiopathic Scoliosis.
Muhammed Yusuf Afacan, Okan Can Karadeniz, Esra Circi, Alican Baris, Emre Ozmen, Serdar Yuksel, Suha Ahmet Aktas
Department of Orthopaedics and Traumatology, Istanbul Physical Therapy and Rehabilitation Training and Research Hospital, Istanbul, Turkey. drmyaorto@gmail.com. · Department of Orthopaedics and Traumatology, Istanbul Physical Therapy and Rehabilitation Training and Research Hospital, Istanbul, Turkey.
Key points
From the paper's conclusion- We compared GPT-5.1 and Gemini 3.1 Pro with a joint expert-consensus reference on 125 anonymized standing coronal whole-spine radiographs.
Abstract
General-purpose multimodal artificial intelligence (AI) models can interpret radiographs through natural-language prompts, but their quantitative agreement and anatomical traceability in adolescent idiopathic scoliosis remain uncertain. We compared GPT-5.1 and Gemini 3.1 Pro with a joint expert-consensus reference on 125 anonymized standing coronal whole-spine radiographs. Each model evaluated each image once in an independent chat session using the same standardized prompt; only the first response was retained. Outcomes included single-measure absolute-agreement intraclass correlation coefficients (ICCs), mean absolute error (MAE) relative to the reference, Bland-Altman analysis, error-threshold performance, categorical agreement, and end-vertebra concordance. Gemini 3.1 Pro showed higher ICC (0.842 versus 0.587), lower mean bias (3.46° versus 8.68°), lower MAE (5.06° versus 9.62°; paired P < 0.001), and more measurements within 5° of the reference (61.6% versus 24.8%). Agreement with reference categories was 80.0% versus 52.8% for angle-derived severity and 78.4% versus 52.8% for prompt-constrained management categories (both paired P < 0.001). Exact upper end-vertebra agreement was 14.4% versus 8.8%, and exact lower end-vertebra agreement was below 20% for both models. Gemini 3.1 Pro performed better under the tested single-session protocol, but neither model demonstrated sufficient case-level agreement and end-vertebra concordance to support autonomous Cobb-angle measurement. These results are relative to expert consensus and do not establish absolute measurement accuracy or model repeatability. Expert verification remains necessary.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Accuracy of general-purpose large language models (LLMS) in interpreting adolescent idiopathic scoliosis radiographs: a comparative study with experienced spine surgeons.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026
- Evaluating the performance of large language models in adolescent idiopathic scoliosis management: a comparative study of prompting strategiesFrontiers in Digital Health · 2026
- Evaluating the readability and quality of AI-generated scoliosis education materials: a comparative analysis of five language modelsScientific Reports · 2025
- Benchmarking Gemini 1.5 Pro in Pediatric Emergency Radiology: Sensitivity Gap and Physiological Bias in the Immature Skeleton.Diagnostics (Basel, Switzerland) · 2026
- Large language models for orthodontic classification using intraoral digital models: a diagnostic accuracy and reproducibility studyBMC Oral Health · 2026
- Consensus-Level and Cluster-Adjusted Evaluation of a Large Language Model for Diagnostic Extraction from Musculoskeletal Radiology ReportsDiagnostics · 2026