Consensus-Level and Cluster-Adjusted Evaluation of a Large Language Model for Diagnostic Extraction from Musculoskeletal Radiology Reports
Wolfram A. Bosbach, Elham Montazeri, Jan F. Senge, Claus Beisbart, Milena Mitrakovic, Suzanne E. Anderson, Eugen Divjak, Gordana Ivanac,
University of Bern · University of Bremen
Key points
From the paper's conclusion- This study evaluates the accuracy of ChatGPT-4.0 when extracting correct diagnoses from musculoskeletal (MSK) radiology text reports, and compares its performance with that of experienced human readers, using cluster-adjusted and consensus-level analyses.
Abstract
Purpose: Large language models (LLMs) may reduce administrative workload in radiology by automating structured diagnostic extraction from text reports. This study evaluates the accuracy of ChatGPT-4.0 when extracting correct diagnoses from musculoskeletal (MSK) radiology text reports, and compares its performance with that of experienced human readers, using cluster-adjusted and consensus-level analyses. Materials and Methods: Twenty-three multimodal MSK imaging cases (X-ray, ultrasound, CT, and MRI) were analysed. Ten human readers and ChatGPT-4.0 (10 independent iterations) provided primary (1st) and secondary (2nd) diagnoses from six predefined options. We analysed data at the individual-reader level using cluster-adjusted generalised estimating equations (GEE) and at the case level using majority consensus with exact McNemar testing. Within-case (α_case) and within-reader (α_reader) correlations and design effects were calculated to assess clustering and implications for sample size. Results: For 1st diagnoses, AI accuracy was 0.957 (95%–CI 0.922–0.976) versus 0.865 (95%–CI 0.815–0.903) for human readers (absolute difference −0.091; OR 3.43, 95%–CI 1.07–11.02; p = 0.038). Within-case correlation (α case = 0.247) exceeded within-reader correlation (α reader ≈ 0); this resulted in a design effect of 5.7 and an effective sample size of 80.7. At the consensus level, discordance occurred in 2/23 cases (8.7%), with no significant difference between methods (McNemar p = 1.00). When 1st and 2nd diagnoses were combined, both systems achieved 23/23 correct consensus classifications. Interrater reliability between AI and human classifications was almost perfect (Gwet’s AC1 = 0.836–0.927). Conclusions and Key points: In this structured MSK text-report setting, ChatGPT-4.0 achieved diagnostic accuracy comparable to that of experienced radiologists, with modest individual-reader advantages that disappeared under consensus aggregation. Clustering analysis indicates that variability is primarily case-driven, suggesting that future validation studies will benefit more from expanding case numbers than reader numbers. Our data suggest that large performance divergences between AI and human consensus are unlikely in similar structured diagnostic contexts.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- The effect of medical explanations from large language models on diagnostic accuracy in radiologynpj Digital Medicine · 2026
- GPT-4.1 and Llama 3.3 70 fail to detect clinically relevant errors in radiology reports in zero-shot evaluationEuropean Radiology · 2026
- Large language models enhance diagnostic reasoning of medical students in rheumatology: a randomized controlled trialBMC Medical Education · 2026
- Certified large language model-based diagnostic decision support in rheumatology: the ALLIANCE multicentre randomised controlled trialmedRxiv · 2026
- Comparative Evaluation of Large Language Models in Explaining Radiology Reports: Expert Assessment of Readability, Understandability, and Communication FeaturesInsights into Imaging · 2025
- Evaluating diagnostic accuracy of large language models in neuroradiology cases using image inputs from JAMA neurology and JAMA clinical challengesScientific Reports · 2025