Evaluating Explicit Anatomical Priors Beyond a Mature CT Detector for Six Acute Abdominal Emergencies.
Hasan Mete Erdoğan, Ural Koç
Budapest University of Technology and Economics, Budapest, Hungary. hasanmete.erdogan@edu.bme.hu. · Department of Radiology, Ankara Bilkent City Hospital, Ankara, Türkiye.
Key points
From the paper's conclusion- To test whether anatomical priors from a general-purpose organ segmentation model (TotalSegmentator, TS), applied at inference or during training, improve an externally validated YOLOv11 detector for six acute abdominal emergencies.
Abstract
To test whether anatomical priors from a general-purpose organ segmentation model (TotalSegmentator, TS), applied at inference or during training, improve an externally validated YOLOv11 detector for six acute abdominal emergencies. The frozen detector was applied to 827 external Stanford Merlin CT studies with language-model report labels; a nested 280-study radiologist-adjudicated subset was the reference standard. TS-derived slice selection (Arm A), organ-state integration (Arm B), and their combination (Arm C) were compared with the detector alone under frozen, recalibrated, and fine-tuned conditions. The detector was also retrained from scratch (identical 10-epoch budget) with image channels only, with the patient's TS organ maps as added input channels, or with another patient's maps. AUROC was primary; comparisons used a paired study-level bootstrap. The detector generalized externally (macro AUROC 0.816 cohort; 0.879 adjudicated). Slice selection was non-inferior but not beneficial: nearly all confident detections already lay within the anchored organ's axial range; organ-state fusion improved AUROC only for cholecystitis (hypothesis-generating). In single runs, training with organ maps raised internal test mAP@0.5 (0.517 versus 0.482), and the model depended on the maps, but external macro AUROC did not improve (0.822 versus 0.829; Δ -0.007, 95% CI -0.019 to +0.007) and kidney-stone AUROC fell (0.678 versus 0.768; exploratory), unlike with another patient's maps. Per-site recalibration was the most effective operating-point adjustment (macro F1 +0.021); annotation-free fine-tuning reduced discrimination. Explicit anatomy, applied after detection or during training, did not improve this detector's overall external discrimination. Per-site recalibration gave the largest operating-point gain.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- An expert-level generalist AI for abdominal CT diagnosis.Science (New York, N.Y.) · 2026
- Anatomy-Activated Mixture-of-Experts for 3D Medical Vision-Language Pre-trainingarXiv · 2026
- Topogram-based anatomical labelling of CT series: anatomy-aware CT data processing using deep learningEuropean Radiology · 2026
- Use of a large language model for identification and extraction of actionable details from recommendations for additional imaging in abdominopelvic CT reports.Abdominal radiology (New York) · 2026
- Multifaceted validation of TotalSegmentator performance in abdominal organ segmentation on CT scans integrated in clinical-grade PACSEuropean Journal of Radiology Artificial Intelligence · 2026
- Reliable and grounded reporting of any computed tomography scan with FORAarXiv · 2026