Use of a large language model for identification and extraction of actionable details from recommendations for additional imaging in abdominopelvic CT reports.
Robert A Frank, Andrew Carney, Amirkasra Mojtahed, Ramin Khorasani, Kristine S Burk, Ronilda Lacson
Brigham and Women's Hospital, Boston, USA. · Harvard Medical School, Harvard University, Boston, USA.
Key points
From the paper's conclusion- GPT-4.1 demonstrated high accuracy for extraction of RAI and enabled accurate extraction of actionable elements. LLM integration into radiology workflows can facilitate automatic closed-loop communication and tracking of recommended imaging, which may reduce diagnostic delays.
Abstract
OBJECTIVE: Automated identification and extraction of recommendations for additional imaging (RAI) from radiology reports could facilitate closed-loop tracking and follow-up completion. We compare a prompt-engineered GPT-4.1 large language model (LLM) versus a validated encoder-only transformer deep learning model (bidirectional encoder representations from transformers [BERT]) for detection of RAI in abdominopelvic computed tomography (CTAP) reports, and evaluate GPT-4.1 for extraction of actionable RAI elements. METHODS: This retrospective study included CTAP reports from a multi-institution system in 2023. LLM and BERT were used to identify RAI from radiology reports; LLM also extracted RAI actionable elements (modality, body part, time frame, rationale). Recall, precision, F1, and accuracy for RAI detection were determined using human-annotated reference standard. Paired comparison between each model's accuracy used McNemar's test. LLM recall, precision, F1, and accuracy for actionable element extraction were computed. Element prevalence was compared using chi-square test. RESULTS: 2000 random reports for unique patients (58% women; mean age 58.5 ± 17.5) included 215 RAI within 206 reports. For RAI detection, GPT-4.1 recall, precision, F1 and accuracy were 95.6%, 98.5%, 97.0% and 99.4%, respectively; BERT recall, precision, F1 and accuracy were 93.7%, 96.5%, 95.1% and 99.0% (p = 0.16). Recommendation element recall were as follows: 100.0% for time frame, 93.9% for body part, 90.2% for rationale, and 94.2% for modality. Precision were 100.0%, 95.7%, 94.6% and 86.1%, respectively. 29/215 (13.5%) RAI were complete (specified all actionable elements). Prevalence of actionable elements varied (p < 0.001), highest for rationale (215/215, 100%), followed by body part (213/215, 99.1%), modality (191/215, 88.8%), and time frame (31/215, 14.4%). CONCLUSION: GPT-4.1 demonstrated high accuracy for extraction of RAI and enabled accurate extraction of actionable elements. LLM integration into radiology workflows can facilitate automatic closed-loop communication and tracking of recommended imaging, which may reduce diagnostic delays.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Optimizing Large Language Models for Automated Protocoling of Abdominal and Pelvic CT Scans: The Power of ContextRadiology · 2026
- RADAR: A Prototype for Grounding Large Language Model Consult Support in an ACR-Structured Appropriateness Knowledge Base with Citation Validation and Abstention.Journal of imaging informatics in medicine · 2026
- Who labels best? Radiologists, rules, or large language modelsfor CT reports on pulmonary embolismEuropean Radiology Experimental · 2026
- GPT-4.1 and Llama 3.3 70 fail to detect clinically relevant errors in radiology reports in zero-shot evaluationEuropean Radiology · 2026
- Toward on-premises RAG pipelines for AI-assisted neuroradiology: practical considerations on privacy, accuracy, and timeliness.BMC medical imaging · 2026
- Case-matched retrieval improves textual alignment of LLM-generated radiology impressionsPLoS ONE · 2026