Effect of toothbrushing mode and brushing load on the wear of anterior tooth-shaped restorative composites.
Elif Alkan, Zeynep Tuğçe Tağtekin, Şevval Nur Tarakçı, Hamit Enis Aslan, Ahmad Bittar, Bora Korkut, Dilek Tağtekin
Department of Restorative Dentistry, Faculty of Dentistry, Marmara University, Istanbul, Turkey. · Faculty of Dentistry, Marmara University, Istanbul, Turkey.
Key points
From the paper's conclusion- The findings do not isolate an intrinsic manual-versus-electric drive-mechanism effect.
Abstract
This in vitro study evaluated the effects of approximately duration-normalized toothbrushing protocols and brushing load on volumetric wear and surface roughness changes of anterior tooth-shaped restorative composite specimens. One hundred twelve specimens were prepared from two highly filled flowable and two paste-type composites in a balanced 2 × 2 × 2 × 2 factorial design. After finishing, polishing, and 10,000 thermal cycles, seven specimens were mounted per manual-brushing run and brushed for 60,000 carriage strokes at 165 strokes/min (total run approximately 364 min; nominal exposure approximately 52 min/specimen), whereas electric brushing was applied for 52 min/specimen. Both protocols were intended to approximate one year of tooth-specific brushing duration but were not mechanically equivalent. Specimens were tested under 1.96-2.94 N. Volumetric loss was assessed using Primescan-based three-dimensional superimposition, and arithmetic mean roughness was measured before and after brushing. Factorial multivariate analysis of variance and follow-up univariate analyses were used. Toothbrushing protocol and load significantly affected the combined outcomes (Pillai trace = 0.926 and 0.827, respectively; both p < 0.001). Under the approximately duration-matched but mechanically different protocols, electric brushing produced greater roughness difference and volumetric loss, and higher load increased both outcomes. The protocol × load interaction was significant for volumetric loss (F = 89.33, p < 0.001). Composite category and trademark were not significant. The findings do not isolate an intrinsic manual-versus-electric drive-mechanism effect.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- In Vitro Evaluation of Manual, Electric, and Sonic Toothbrushing on Composite Restoration Surface Properties and Retention in Primary Teeth.Dentistry journal · 2026
- Effect of Simulated Toothbrushing on Surface Roughness, Color Stability, and Gloss of Two Single-Shade Composite ResinsMaterials · 2026
- Surface Roughness and Color Stability of S-PRG Giomer Flowable Restoratives Versus Nanofill Resin Composites After Simulated Toothbrushing: An In Vitro Study.Polymers · 2026
- Intraoral Scanner Evaluation of Cyclic Wear in Heated Versus Injectable Composites for Indirect Restoration.European journal of dentistry · 2026
- Effect of Finishing Protocols and Simulated Toothbrushing on the Surface Roughness and Color Stability of Conventionally and Digitally Fabricated Interim Restorative MaterialsCoatings · 2026
- In vitro evaluation of sliding contact wear performance in direct resin-based composites with varying inorganic filler loadings.Journal of the mechanical behavior of biomedical materials · 2026