Axillary microaxial flow pump support for stepwise source control and bridge to durable left ventricular assist device therapy in cardiac device-related infective endocarditis.
Yohei Tamura, Shiro Nakahara, Masahito Saito, Kei Torikai, Koichi Toda, Isao Taguchi
Department of Cardiology, Dokkyo Medical University Saitama Medical Center, 2-1-50 Minami Koshigaya, Koshigaya, Saitama, 343-8555, Japan. · Department of Cardiology, Dokkyo Medical University Saitama Medical Center, 2-1-50 Minami Koshigaya, Koshigaya, Saitama, 343-8555, Japan. nshiro@dokkyomed.ac.jp.
Key points
From the paper's conclusion- This case suggests that axillary Impella 5.5 support may provide a stabilizing platform for staged source control, high-risk lead extraction, end-organ recovery, and bridge to durable mechanical circulatory support in carefully selected patients.
Abstract
Cardiac device-related infective endocarditis complicated by end-stage heart failure poses a major therapeutic challenge because complete hardware removal is essential, whereas transvenous lead extraction may be poorly tolerated in patients with severe ventricular dysfunction and shock. We report a 53-year-old man with long-standing dilated cardiomyopathy and cardiac resynchronization therapy-defibrillator infection who presented with methicillin-sensitive Staphylococcus aureus bacteremia, pocket infection, respiratory failure, acute kidney injury, and a clinical presentation consistent with mixed septic-cardiogenic shock. Transthoracic echocardiography showed severe left ventricular dilatation and an ejection fraction of 10%. Because immediate extraction of a 17-year-old defibrillator lead was considered extremely high risk, an Impella 5.5 was implanted via the right subclavian artery, and surgical pocket drainage was performed as initial source control. After hemodynamic stabilization and reduction of vasoactive requirements, complete transvenous extraction of all leads was performed on hospital day 6 under ongoing Impella 5.5 support and cardiovascular surgical backup. During defibrillator lead traction, pulmonary artery pressure transiently decreased, but sustained systemic hemodynamic collapse did not occur. Following prolonged intravenous antibiotic therapy, blood cultures remained negative, renal function recovered sufficiently to discontinue continuous hemodiafiltration, and the patient was transferred to an advanced heart failure center. Durable left ventricular assist device implantation was subsequently performed successfully. This case suggests that axillary Impella 5.5 support may provide a stabilizing platform for staged source control, high-risk lead extraction, end-organ recovery, and bridge to durable mechanical circulatory support in carefully selected patients.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Microaxial Flow Pump and Ivabradine for Tachycardia-Induced Cardiogenic Shock Caused by Automatic Atrial Tachycardia.JACC. Case reports · 2026
- A case report of pacemaker endocarditis presenting as osteitis in a high-surgical-risk patient: a management challenge with thromboaspiration and leadless pacemaker implantation.European heart journal. Case reports · 2026
- Exploratory proof-of-concept study and failure mode analysis of a dual-lumen stent graft for transapical off-pump LVAD implantation.Scientific reports · 2026
- 276 Days of Support by a Micro-Axial Left Ventricular Assist Device as a Bridge to Heart Transplant.Artificial organs · 2026
- Impella in infarction-related cardiogenic shock: evidence, complications, and implementation of microaxial LV unloading.Medizinische Klinik, Intensivmedizin und Notfallmedizin · 2026
- Safety and Outcomes of Percutaneous Vegetation Aspiration During Transvenous Lead Extraction: A Multicenter Experience.Journal of cardiovascular electrophysiology · 2026