Clinical oral investigations

Resin composites for clear aligner attachments: staining resistance, whitening response, and degree of conversion.

Rebeca J G Rodrigues, Vinicius H Hutemma, Giulia G Pizzanelli, Adriano F Lima, Bruna M Fronza, Matheus Kury, Michelle Sendyk

Dental Research Division, Graduate Program in Dentistry, Paulista University (UNIP), Rua Dr. Bacelar 1212, Vila Clementino, São Paulo, SP, 04026-002, Brazil. · Hospital Israelita Albert Einstein, São Paulo, Brazil.

Key points

From the paper's conclusion
  • Staining and whitening responses depended on resin composite and staining solution. OPFlow, which is not specifically directed for attachment fabrication, generally showed lower residual staining after bleaching. In addition, polymerization characteristics differed among materials.

Abstract

OBJECTIVES: This study evaluated the staining resistance and whitening response of resin composites indicated for clear aligner attachment fabrication compared with restorative composites and characterized their polymerization kinetics. METHODS: Discs of Aligner Flow LC (AFlow), Transbond® Supreme LV (LVFlow), Opallis (OPFlow), and Filtek Z350XT were exposed to coffee (CF), red wine (RW), cola drink (CO), or artificial saliva (AS), followed by daily bleaching with 10% hydrogen peroxide. Color changes (ΔE00) and Whiteness Index for Dentistry changes (ΔWID) were analyzed by spectrophotometry (n = 10/group) at baseline (T0), after staining (T1), and after bleaching (T2). Degree of conversion (DC) and maximum polymerization rate (Rpmax) were assessed by FT-IR. Data were analyzed using generalized linear models (α = 5%). RESULTS: At T1-T0, CF and RW produced greater staining than CO and AS, while OPFlow showed the lowest color changes, particularly after CF exposure (p < 0.05). At T2-T1, the whitening response depended on the previous staining solution and composite, with greater changes after RW exposure. At T2-T0, CF and RW resulted in the greatest residual color changes, whereas OPFlow showed the lowest residual staining, particularly under CF and RW (p < 0.05). DC differed significantly among the tested composites (p < 0.05), and OPFlow presented the highest RPmax (p < 0.05). CONCLUSIONS: Staining and whitening responses depended on resin composite and staining solution. OPFlow, which is not specifically directed for attachment fabrication, generally showed lower residual staining after bleaching. In addition, polymerization characteristics differed among materials. CLINICAL SIGNIFICANCE: Resin composites specifically formulated and indicated for clear aligner attachment fabrication showed greater susceptibility to staining than a general-purpose flowable composite. Whitening procedures reduced discoloration but did not fully reverse staining in the attachment-specific materials.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers