Comparison of cone beam computed tomography measurements obtained after manual and AI-assisted head positioning and reconstruction.
Bruno Werlang, Débora Costa Ruiz, Amanda Flor, Monikelly do Carmo Chagas Nascimento, Anne Caroline Oenning
Division of Oral Radiology, Faculdade São Leopoldo Mandic, Instituto de Pesquisas São Leopoldo Mandic, Campinas, SP, Brazil. · Department of Clinical Dentistry, Federal University of Espírito Santo (UFES), Espírito Santo, Brazil. ruiz03338@gmail.com.
Key points
From the paper's conclusion- Measurements obtained with the AI-assisted method for volume repositioning and generation of panoramic and cross-sectional images were comparable to those obtained using a conventional method.
Abstract
OBJECTIVES: To compare measurements obtained from cone beam computed tomography (CBCT) exams by radiologists following manual head positioning and panoramic curve tracing with those obtained after artificial intelligence (AI)-assisted positioning adjustments performed prior to measurement. MATERIALS AND METHODS: Twenty-five CBCT exams presenting edentulous sites corresponding to missing mandibular first molars were selected. Five examiners performed measurements of bone height and width after manual head positioning adjustments and panoramic curve tracing (manual method). Subsequently, the same exams were processed using TomoNav software, which automatically performed volume alignment and generated the panoramic curve and cross-sectional images. The examiners then repeated the measurements (AI-assisted method). Measurements obtained from both approaches were summarized using descriptive statistics and compared using the intraclass correlation coefficient (ICC), paired t-test, and Bland-Altman analysis (p˂0.05). RESULTS: Excellent inter-examiner reproducibility was observed for both height and width measurements, with ICC values of 0.94 for height and 0.81 and 0.85 for width using the manual and AI-assisted methods, respectively. Significant differences were identified for left-side height, total height, right-side width, and total width (p < 0.05). However, the mean biases were low and overall agreement between methods was excellent, with ICC values equal or greater than 0.89. CONCLUSION: Measurements obtained with the AI-assisted method for volume repositioning and generation of panoramic and cross-sectional images were comparable to those obtained using a conventional method. CLINICAL RELEVANCE: AI facilitates CBCT implant-planning preprocessing without compromising measurement reproducibility.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Reliability of AI-driven cephalometric analysis on CBCT: comparison with manual 2D cephalometryProgress in Orthodontics · 2026
- Artificial Intelligence-Assisted Cone-Beam Computed Tomography Analysis in Alveolar Ridge Preservation: A Narrative Review.European journal of dentistry · 2026
- A comparison of panoramic views reformatted from CBCT scans using manual or automated workflows: an evaluation of geometric accuracy and subjective image quality.Clinical oral investigations · 2026
- Agreement and reproducibility of intraoral scan- versus CBCT-based three-dimensional implant position assessment in the posterior mandible - a paired in vitro method-comparison study.International journal of implant dentistry · 2026
- Quantitative Comparison of Bone and Dental Morphology Between Invisalign® Integrated CBCT Images and Conventional CBCT Images.Dentistry journal · 2026
- Accuracy and efficiency of artificial intelligence 3-dimensional segmentation and construction of cone-beam computed tomography images for impacted maxillary canines compared with the manual method.American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics · 2026