Key points
From the paper's conclusion- The CCC for RR during controlled breathing was 0.992, and that for HR post-exercise was 0.982, remaining excellent for both RR and HR under various dental vibrations.
- The Taido Sensor demonstrates high concordance with reference methods for vital signs measurements in routine dental practice, maintaining accuracy despite mechanical interference from dental instruments.
Abstract
OBJECTIVES: Vital signs are not routinely monitored in dental practice, potentially delaying the recognition of medical emergencies. This study aimed to evaluate the accuracy of a piezoelectric sensor (Taido Sensor, Sumitomo Riko Co., Ltd., Nagoya, Japan) for measuring respiratory rate (RR) and heart rate (HR). Resilience against vibrations from cutting instruments was also assessed. MATERIALS AND METHODS: Fifteen healthy participants were monitored on a dental chair fitted with the sensor. Respiratory inductive plethysmography and electrocardiography served as reference methods. Three protocols were executed: (1) controlled breathing at 6-28 breaths/min; (2) HR recovery following a 3-min Master's two-step exercise test; and (3) clinical vibration simulated using an ultrasonic scaler, air turbine, and micromotors. RR and HR were derived from 30-s and 10-s waveform segments, respectively. Agreement was assessed using Lin's concordance correlation coefficient (CCC) and Bland-Altman analysis. RESULTS: The CCC for RR during controlled breathing was 0.992, and that for HR post-exercise was 0.982. CCCs remained excellent for both RR (0.968-0.997) and HR (0.954-0.997) under various dental vibrations. Bland-Altman analysis revealed minimal fixed bias and clinically acceptable limits of agreement across all conditions. CONCLUSIONS: The Taido Sensor demonstrates high concordance with reference methods for vital signs measurements in routine dental practice, maintaining accuracy despite mechanical interference from dental instruments. CLINICAL RELEVANCE: Owing to its contactless design and ability to provide reliable data from short segments, the Taido Sensor could be a valuable tool for monitoring real-time vital signs during routine dental procedures, thereby enhancing patient safety.
Read the paper
Discussion · 1
Science Skim's AI key points, plus readers' public thoughts
- The CCC for RR during controlled breathing was 0.992, and that for HR post-exercise was 0.982, remaining excellent for both RR and HR under various dental vibrations.
- The Taido Sensor demonstrates high concordance with reference methods for vital signs measurements in routine dental practice, maintaining accuracy despite mechanical interference from dental instruments.
Readers' thoughts
No reader thoughts yet.
Related papers
- Real-Time Subjective and Physiological Responses During Dental Treatment: Temporal Characteristics of Skin Temperature and Electrodermal Activity.Sensors (Basel, Switzerland) · 2026
- A Wearable Morphic Sensor for Unobtrusive Heart Rate and Respiratory Rate Monitoring in ICU Patients: A Pilot Validation Study.Sensors (Basel, Switzerland) · 2026
- Non-Pharmacologic Interventions for Hemodynamic Stability During Dental Implant Surgery: A Randomized Controlled Trial.Clinical implant dentistry and related research · 2026
- Aerosol mitigation efficiency of high-volume suction systems during aerosol-generating dental procedures with patients.Annals of work exposures and health · 2026
- Perception and accuracy of an AI-based contactless wellness screening system in dental setting; a cross-sectional study.The Saudi dental journal · 2026
- Pilot validation of a piezo‑resistive gnathodynamometer for maximum voluntary bite force measurement in adults: a cross sectional comparative study.BMC oral health · 2026