A Wearable Morphic Sensor for Unobtrusive Heart Rate and Respiratory Rate Monitoring in ICU Patients: A Pilot Validation Study.
Titus Jayarathna, Caitlin Polley, Paul P Breen, Gaetano D Gargiulo, Anders Aneman
The MARCS Institute for Brain, Behaviour and Development, Western Sydney University, Locked Bag 1797, Penrith, NSW 2751, Australia. · School of Engineering, Western Sydney University, Locked Bag 1797, Penrith, NSW 2751, Australia.
Key points
From the paper's conclusion- The proposed system met the pre-specified bias and standard deviation criteria for HR and RR monitoring in bed-bound ICU patients. Its skin-adhesive-free design enables unobtrusive, continuous vital sign surveillance without direct skin contact. These findings support ICU monitoring. Step-down ward and ambulatory applications remain to be validated in future studies.
Abstract
PURPOSE: This pilot study evaluated the real-world accuracy of a novel wearable morphic sensor system for unobtrusive, continuous heart rate (HR) and respiratory rate (RR) monitoring in critically ill patients within an intensive care unit (ICU). METHODS: A hybrid piezoresistive/piezoelectric disk-shaped sensor was placed on patients' backs to capture cardiorespiratory activity via forcecardiographic principles. Data were acquired from 15 ICU patients using a custom wireless recorder. The piezoelectric channel was processed using discrete wavelet transform and an adaptive peak detection algorithm. Derived HR and RR were compared against reference measurements from clinical patient monitors and a ventilator. RESULTS: Bland-Altman analysis showed a mean bias of -0.39 ± 1.99 beats per minute for HR and 0.06 ± 0.90 breaths per minute for RR. Linear regression revealed strong correlation with clinical monitors (HR R-squared = 0.982; RR R-squared = 0.966). The device's RR performance matched the agreement between two independent clinical reference devices. CONCLUSION: The proposed system met the pre-specified bias and standard deviation criteria for HR and RR monitoring in bed-bound ICU patients. Its skin-adhesive-free design enables unobtrusive, continuous vital sign surveillance without direct skin contact. These findings support ICU monitoring. Step-down ward and ambulatory applications remain to be validated in future studies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Development and validation of an integrated wearable system for continuous cardiorespiratory monitoring using photoplethysmography and optical respiratory detection.Medical & biological engineering & computing · 2026
- Clinical Evaluation of a Multimodal On-Body Sensor Array.medRxiv : the preprint server for health sciences · 2026
- Seismo-Mat: mattress-embedded inertial sensors for unobtrusive monitoring of heart rate, respiratory rate, and bed occupancy during sleep.IEEE transactions on bio-medical engineering · 2026
- H ygieia : A Wearable Metamaterial Patch for Calibration-free Carotid Hemodynamics MonitoringProceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies · 2026
- Multimodal Wearable Sensor System for Continuous Peripheral Circulation Monitoring in Postoperative Flap Care.Advanced healthcare materials · 2026
- Wearable Textile Microwave Sensor for Wrist Pulse Wave and Heart Rate MonitoringIEEE Sensors Journal · 2026