In vitro evaluation of the efficacy of a new orthodontic primer in metallic brackets cementation
Byron Carpio–Salvatierra, Mayra Alejandra Nuñez, Pamela Maria Kusdra, Victor Martins Montalli, Ana del Carmen Armas Vega, Paulo Vítor Farago, Alessandro D. Loguercio
Universidade Estadual de Ponta Grossa · Universidad San Francisco de Quito
Key points
From the paper's conclusion- Ambar APS Ortho exhibited superior performance in both SBS and DC, for both 3 s and 10 s light-curing times as well as IT or AT, supporting its reliability for bonding metallic orthodontic brackets.
Abstract
OBJECTIVE: To evaluate the efficacy of a new orthodontic primer (Ambar APS Ortho; FGM Dental Products, Joinville, SC, Brazil) on shear bond strength (SBS) and degree conversion (DC) of metallic brackets bonding. MATERIALS AND METHODS: 240 sound maxillary premolars were randomized into 24 experimental groups based on: (1) Orthodontic primer (Ambar APS Ortho, Orthoprimer and Transbond XT); (2) Light-curing time (3-seconds and 10-seconds); (3) Light-curing unit (Valo Cordless and Quazar); and (4) Storage condition (immediate time [IT] and after thermocycling [TC]). After each storage time, specimens were subjected to SBS testing at a crosshead speed of 1 mm/min until failure, and values were recorded in MPa. For DC (%) analysis, adhesive discs were prepared and evaluated using micro-Raman spectroscopy at IT only. SBS and DC data were analyzed using four and four-way ANOVA, respectively and Tukey's post hoc test (α = 0.05). RESULTS: Ambar APS Ortho showed significantly higher SBS values across both light-curing units compared to all other groups (p = 0.0001). For DC, Orthoprimer showed the lowest values, while Ambar APS Ortho achieved the highest. Across all primers, a 10 s light-curing exposure resulted in significantly higher DC values compared to 3 s (p < 0.0001). CONCLUSIONS: Ambar APS Ortho exhibited superior performance in both SBS and DC, for both 3 s and 10 s light-curing times as well as IT or AT, supporting its reliability for bonding metallic orthodontic brackets.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effect of Metal Primer Application on the Shear Bond Strength of Orthodontic Brackets with Different Base Designs: An In Vitro Study.Dentistry journal · 2026
- The effect of different intensity modes and curing times of new-generation LED light-curing units and orthodontic adhesives on shear bond strength of metal brackets.Korean journal of orthodontics · 2026
- Shear bond strength of metal and plastic orthodontic brackets bonded to 3D‑printed UDMA provisional resin restorations after surface treatments and aging: an in vitro study.Odontology · 2026
- Effect of LED Light-Curing Distance on Microhardness and Bracket Bonding Performance: An In Vitro Study.Dentistry journal · 2026
- Evaluation of shear bond strength of orthodontic ceramic and metal brackets with zirconia: effects of adhesive systems and storage conditionsClinical Oral Investigations · 2026
- Effect of light-emitting diode curing tip distance on shear bond strength in metal, ceramic and polycarbonate orthodontic brackets: An in vitro study.Bioinformation · 2026