Mikrochimica acta

Synergistic optimization of sensitivity and point-of-care performance: orthogonal readout SERS-LFA for multiplexed precise detection.

Yuhang Que, Ling Xin, Hengrui Cui, Li Wang, Zhuang Li

Key Laboratory of Preparation and Application of Environmental Friendly Materials, Ministry of Education, College of Chemistry, Jilin Normal University, Siping, 136000, China. · Key Laboratory of Preparation and Application of Environmental Friendly Materials, Ministry of Education, College of Chemistry, Jilin Normal University, Siping, 136000, China. liwang@jlnu.edu.cn.

Review

Key points

From the paper's conclusion
  • Focusing on the inherent trade-off between sensitivity enhancement and on-site applicability, it evaluates the pros and cons of strategies including nanotag engineering, signal amplification, ratiometric calibration, portable readout, pretreatment, and strip stability, discusses the signal coupling risks of mainstream colorimetric-SERS and fluorescence-SERS architectures, elucidates the synergisti

Abstract

Traditional surface-enhanced Raman scattering-based lateral flow assay (SERS-LFA) breaks through the sensitivity bottleneck of conventional LFAs, yet existing multi-modal studies often conflate orthogonal readout, encoding strategies, and pretreatment approaches. They lack quantitative verification of channel independence, making it difficult to balance anti-interference performance in complex matrices with the requirements of on-site point-of-care testing (POCT). Built on the operational criteria for orthogonal readout, this review clarifies its conceptual boundaries with ratiometric sensing, multiplex encoding, and magnetic enrichment, and analyzes the SERS signal mechanism, design constraints of nanotags, and the compatibility logic of sandwich and competitive immunoassay formats. Focusing on the inherent trade-off between sensitivity enhancement and on-site applicability, it evaluates the pros and cons of strategies including nanotag engineering, signal amplification, ratiometric calibration, portable readout, pretreatment, and strip stability, discusses the signal coupling risks of mainstream colorimetric-SERS and fluorescence-SERS architectures, elucidates the synergistic relationship between orthogonal readout and encoding strategies, and identifies the remaining limitations of machine learning in multi-channel data interpretation. Addressing current shortcomings in probe consistency, strip signal drift, device generalization capability, and methodological evaluation frameworks, this review puts forward development directions including rational probe design, integrated hardware-software systems, dataset construction, and standardized large-sample validation, providing guidance for the rigorous construction, performance assessment, and on-site POCT translation of orthogonal readout-based SERS-LFA.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers