Mikrochimica acta

Probe-mediated subcellular organelles translocation enabled ratiometric quantification of nitroreductase activity and microviscosity for hypoxia imaging and precise tumor delineation.

Chen-Ye Jin, Hui-Quan Xiao, Xiao-Shi Fan, Zhi-Hao Lu, Yue-Rui Kong, Yue Yan, Zi-Yan Sun, Xiao-Ling Yang,

College of Chemistry and Chemical Engineering, Shaoxing University, Shaoxing, 312000, P. R. China. · Key Laboratory of Life-Organic Analysis of Shandong Province, School of Chemistry and Chemical Engineering, Qufu Normal University, Qufu, 273165, P. R. China.

Key points

From the paper's conclusion
  • Our subcellular organelle translocation strategy proposed in this study offers a novel approach to mitigating ACQ effect in quantification assignment, and the high-performance NIR fluorescent probe drafted in this work provides a prospective tool for precise tumor diagnosis and intraoperative navigation via multi-parameter imaging of hypoxic tumor microenvironment.

Abstract

Quantitative assessment of hypoxia-induced nitroreductase (NTR) upregulation and pathological viscosity elevation offers a critical diagnostic parameter for precise cancer diagnostics.​ We propose a subcellular organelle translocation strategy for ultrasensitive quantification of NTR/microviscosity and subsequent precise evaluation of tumor hypoxia levels. The constructed NTR-sensitive probe Cy826 releases the fluorophore Cy468 upon NTR catalysis, accompanied by a significant fluorescence turn-on response (21.9-fold enhancement) and subcellular organelle translocation from endoplasmic reticulum (ER) to lysosomes, which effectively reduced local probe accumulation and significantly alleviated the aggregation-caused quenching (ACQ) effect and spectral crosstalk in quantification process. The cyclen-based hemicyanine Cy468 is a fluorophore distinct from our previously reported Cy496, with near-infrared (NIR) emission (~ 720 nm), lower logP, and lysosomal rather than mitochondrial targeting. Cy826 displays high sensitivity (LOD = 8.2 ng/mL) and excellent selectivity toward NTR, along with a strong fluorescence enhancement under high viscosity and molecular crowding conditions. The probe also facilitates real-time monitoring of viscosity changes in ER and lysosomes, and dynamically responds to endogenous NTR activity under varying hypoxia levels. Moreover, after administration of Cy826, the considerable tumor-to-background ratio (TBR > 12) enables high-contrast imaging of hypoxic tumors from early to advanced stages with favorable biocompatibility and metabolic characteristics. Our subcellular organelle translocation strategy proposed in this study offers a novel approach to mitigating ACQ effect in quantification assignment, and the high-performance NIR fluorescent probe drafted in this work provides a prospective tool for precise tumor diagnosis and intraoperative navigation via multi-parameter imaging of hypoxic tumor microenvironment.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers