Mikrochimica acta

Machine learning-assisted Ti3C2Tx MXene/Au@Fe3O4 core-shell nanocomposite-based electrochemical genosensor for ultrasensitive detection of EGFR T790M mutation in lung cancer.

Fatemeh Maleki, Mohammad Rashidi, Jalal Hanaee, Ali Esfahani, Amir Vahedi, Mohammad-Reza Rashidi

Department of Medicinal Chemistry, Faculty of Pharmacy, Tabriz University of Medical Sciences, Tabriz, Iran. · Independent Researcher, Melbourne, Australia.

Computational

Key points

From the paper's conclusion
  • Finally, tissue and pleural fluid samples obtained from lung cancer patients were evaluated using the designed genosensor.

Abstract

​A label-free, sensitive, and selective electrochemical genosensor based on DNA hybridization was designed to detect the T790M mutation in the EGFR gene. This mutation is observed in some patients undergoing treatment for non-small cell lung cancer due to the development of drug resistance. The mentioned genosensor was prepared by modifying the surface of a screen-printed carbon electrode (SPCE) with a Ti3C2TX MXene/Au@Fe3O4 core-shell nanocomposite. MXene nanosheets with abundant functional groups led to increased electrical conductivity and surface area. Also, Au@Fe3O4 nanostructures, in addition to enhancing conductivity, led to the stabilization of the thiolated biomolecules on the surface of the designed electrode. To effectively investigate of the structural and morphological characteristics of the synthesized nanoparticles, different characterization techniques, including FE-SEM, UV-Vis, VSM, EDS, FTIR, and XRD were applied. To further improve the sensor performance, several machine learning algorithms were systematically evaluated to identify the most predictive alternative model. Bayesian optimization (BO) was then used to efficiently explore and optimize the experimental parameter space. Under optimal conditions, the linear range, sensitivity LOD and LOQ were obtained as 1 pM - 1 µM, 69.97 µA cm- 2.dec, 226 fM and 755 fM, respectively. Furthermore, the designed genosensor showed acceptable selectivity in the presence of non-complementary oligonucleotide sequences. Finally, tissue and pleural fluid samples obtained from lung cancer patients were evaluated using the designed genosensor. The concentration of the mutated gene in these samples was measured, and the results were effectively compared with real-time PCR results to verify the accuracy of the method.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers