Mikrochimica acta

A Sm-MOF@Ag electrochemiluminescence immunosensor mediated by CuBi2O4@PDA dual-mode quenching for sensitive detection of anti-Müllerian hormone.

Xuemin Qin, Xiangfei Zheng, Xuyang Deng, Zhi Luo, Shenglan Hu, Jing Li, Biyang Deng

Key Laboratory for Chemistry and Molecular Engineering of Medicinal Resources (Ministry of Education of China), Guangxi Key Laboratory of Chemistry and Molecular Engineering of Medicinal Resources, University Engineering Research Center for Chemistry of Characteristic Medicinal Resources (Guangxi), School of Chemistry and Pharmaceutical Sciences, Guangxi Normal University, Guilin, 541004, China. · Key Laboratory for Chemistry and Molecular Engineering of Medicinal Resources (Ministry of Education of China), Guangxi Key Laboratory of Chemistry and Molecular Engineering of Medicinal Resources, University Engineering Research Center for Chemistry of Characteristic Medicinal Resources (Guangxi), School of Chemistry and Pharmaceutical Sciences, Guangxi Normal University, Guilin, 541004, China. dengby16@163.com.

Key points

From the paper's conclusion
  • By exploiting the dual-quenching effect of CuBi2O4@PDA on Sm-MOF@Ag, we developed a signal-on/signal-off electrochemiluminescence (ECL) immunosensor for the sensitive detection of anti-Müllerian hormone (AMH).

Abstract

By exploiting the dual-quenching effect of CuBi2O4@PDA on Sm-MOF@Ag, we developed a signal-on/signal-off electrochemiluminescence (ECL) immunosensor for the sensitive detection of anti-Müllerian hormone (AMH). A novel samarium-based metal-organic framework (Sm-MOF) was employed as the luminophore, with K2S2O8 used as the co-reactant to generate a stable ECL signal. Silver nanoparticles were in situ decorated on the Sm-MOF surface to act as co-reactant accelerators, promoting SO4•- generation and significantly enhancing the ECL intensity. For signal quenching, energy transfer from the Sm-MOF@Ag donor to the CuBi2O4 acceptor was rationally designed based on their matched energy levels, resulting in pronounced attenuation of the ECL emission. Meanwhile, the polydopamine shell further improved the quenching efficiency by scavenging SO4•- radicals. Under optimized conditions, the proposed ECL immunosensor exhibited a wide linear range from 10 fg·mL- 1 to 100 ng·mL- 1 and a detection limit of 2.6 fg·mL- 1. This dual-quenching strategy represents a novel method for the detection of AMH, with substantial potential for implementation in clinical diagnostics.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers