A Sm-MOF@Ag electrochemiluminescence immunosensor mediated by CuBi2O4@PDA dual-mode quenching for sensitive detection of anti-Müllerian hormone.
Xuemin Qin, Xiangfei Zheng, Xuyang Deng, Zhi Luo, Shenglan Hu, Jing Li, Biyang Deng
Key Laboratory for Chemistry and Molecular Engineering of Medicinal Resources (Ministry of Education of China), Guangxi Key Laboratory of Chemistry and Molecular Engineering of Medicinal Resources, University Engineering Research Center for Chemistry of Characteristic Medicinal Resources (Guangxi), School of Chemistry and Pharmaceutical Sciences, Guangxi Normal University, Guilin, 541004, China. · Key Laboratory for Chemistry and Molecular Engineering of Medicinal Resources (Ministry of Education of China), Guangxi Key Laboratory of Chemistry and Molecular Engineering of Medicinal Resources, University Engineering Research Center for Chemistry of Characteristic Medicinal Resources (Guangxi), School of Chemistry and Pharmaceutical Sciences, Guangxi Normal University, Guilin, 541004, China. dengby16@163.com.
Key points
From the paper's conclusion- By exploiting the dual-quenching effect of CuBi2O4@PDA on Sm-MOF@Ag, we developed a signal-on/signal-off electrochemiluminescence (ECL) immunosensor for the sensitive detection of anti-Müllerian hormone (AMH).
Abstract
By exploiting the dual-quenching effect of CuBi2O4@PDA on Sm-MOF@Ag, we developed a signal-on/signal-off electrochemiluminescence (ECL) immunosensor for the sensitive detection of anti-Müllerian hormone (AMH). A novel samarium-based metal-organic framework (Sm-MOF) was employed as the luminophore, with K2S2O8 used as the co-reactant to generate a stable ECL signal. Silver nanoparticles were in situ decorated on the Sm-MOF surface to act as co-reactant accelerators, promoting SO4•- generation and significantly enhancing the ECL intensity. For signal quenching, energy transfer from the Sm-MOF@Ag donor to the CuBi2O4 acceptor was rationally designed based on their matched energy levels, resulting in pronounced attenuation of the ECL emission. Meanwhile, the polydopamine shell further improved the quenching efficiency by scavenging SO4•- radicals. Under optimized conditions, the proposed ECL immunosensor exhibited a wide linear range from 10 fg·mL- 1 to 100 ng·mL- 1 and a detection limit of 2.6 fg·mL- 1. This dual-quenching strategy represents a novel method for the detection of AMH, with substantial potential for implementation in clinical diagnostics.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A dual-quenching electrochemiluminescence immunosensor based on ABEI@Fe3O4@PDA-PdPt and Cu2-xS nanoflowers for sensitive detection of galectin-3.Mikrochimica acta · 2026
- A Metal-Organic Framework-Based Electrochemiluminescence Immunosensor with Dual Quenching via Resonance Energy Transfer and Radical Scavenging.ACS omega · 2026
- A triple-quenching probe enabling signal amplification for high-performance electrochemiluminescence biosensing.Bioelectrochemistry (Amsterdam, Netherlands) · 2026
- MOF-regulated aggregation-induced electrochemiluminescence for machine learning-assisted aptasensing of cancer marker.Talanta · 2026
- Efficient Electrochemiluminescent Ce−Cu Bimetal−Organic Framework with Self-Catalytic AIECL Performance for Constructing Biosensing Platform Integrated with an Allosteric Stem-Loop DNAzyme-Localized CHA Cyclic Amplification StrategyAnalytical Chemistry · 2026
- Covalent Bridging Achieves Nanorestriction Enhanced Aggregation-Induced Electrochemiluminescence for 17β-Estradiol ECL Imaging-Assisted Dual-Mode ECL/EC DetectionAnalytical Chemistry · 2026