A dual-quenching electrochemiluminescence immunosensor based on ABEI@Fe3O4@PDA-PdPt and Cu2-xS nanoflowers for sensitive detection of galectin-3.
Tingting Ye, Zhu Wang, Xinxin Chen, Xia Zhang, Yi Chen, Xinyi Yu, Zhangbo Dong, Haoyuan Wu,
Emergency and Critical Care Center, Department of Emergency Medicine, Affiliated People's Hospital, Zhejiang Provincial People's Hospital, Hangzhou Medical College, Hangzhou, Zhejiang, China. · School of Public Health, Hangzhou Medical College, Hangzhou, China.
Key points
From the paper's conclusion- This work presents a novel strategy for the highly sensitive detection of Gal-3, leveraging the synergistic dual-quenching mechanism to achieve excellent analytical performance, thereby holding significant promise for clinical diagnostics and early disease monitoring applications.
Abstract
Galectin-3 (Gal-3) is a critical biomarker for the diagnosis and prognosis of cardiovascular diseases and tumors, necessitates highly sensitive detection for clinical applications. In this study, a dual-quenching electrochemiluminescence (ECL) immunosensor was developed for the ultrasensitive detection of Gal-3. The sensor employed an N-(4-aminobutyl)-N-ethylisoluminol (ABEI) @Fe3O4@PDA-PdPt composite as an efficient luminophore, where the material's exceptional conductivity and catalytic properties significantly amplified the ECL signal. For signal quenching, secondary antibody-labeled copper-deficient copper sulfide nanoflowers (Ab2-Cu2-xS NFs) were introduced. These nanoflowers enabled a dual-quenching effect through the synergistic mechanisms of resonance energy transfer (RET) and defect-assisted electron dissipation. A sandwich-type ECL immunosensing platform was constructed by sequentially immobilizing the capture antibody, target antigen, and Ab2-Cu2-xS NFs. Under optimized conditions, the proposed immunosensor demonstrated a broad linear detection range for Gal-3 from 1 pg·mL⁻¹ to 500 ng·mL⁻¹, with an exceptionally low detection limit of 24 fg·mL⁻¹. Additionally, the sensor exhibited outstanding specificity, stability, and reproducibility. This work presents a novel strategy for the highly sensitive detection of Gal-3, leveraging the synergistic dual-quenching mechanism to achieve excellent analytical performance, thereby holding significant promise for clinical diagnostics and early disease monitoring applications. The successful construction of this platform also provides a valuable reference for developing advanced ECL systems for other biomarkers.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Sm-MOF@Ag electrochemiluminescence immunosensor mediated by CuBi2O4@PDA dual-mode quenching for sensitive detection of anti-Müllerian hormone.Mikrochimica acta · 2026
- Confined ZrO2 possessing triple catalytic functionality boosts luminol-dissolved oxygen electrochemiluminescence for immunoassay.Talanta · 2026
- A Metal-Organic Framework-Based Electrochemiluminescence Immunosensor with Dual Quenching via Resonance Energy Transfer and Radical Scavenging.ACS omega · 2026
- Co-CdO-Amplified Electrochemiluminescence of GSH-AuNCs Immobilized on Fe-MIL-88A for Ultrasensitive Immunosensing of Carbohydrate Antigen 15-3Analytical Chemistry · 2025
- A versatile AuNPs@UiO-66-based electrochemiluminescent immunosensing platform for sensitive detection of talin proteins.Mikrochimica acta · 2026
- A triple-quenching probe enabling signal amplification for high-performance electrochemiluminescence biosensing.Bioelectrochemistry (Amsterdam, Netherlands) · 2026