Increased screw backout with non–inlay design retrograde femoral nails
Benyamin Dadpey, Kevin Zhu, Noah Swärd, Allen Dao, William T. Kent
University of California San Diego
Key points
From the paper's conclusion- The ultra-high molecular weight polyethylene (UHMWPE) inlay at the distal interlocking interface of a retrograde femoral nail was associated with significantly lower rates of distal interlocking screw backout and symptomatic screw removal. When backout did occur, polyethylene inlay did not impact time to diagnosis and backout distance.
Abstract
Abstract Purpose To compare the rate of distal interlocking screw backout between inlay-design and non-inlay design retrograde intramedullary femoral nails in the treatment of distal femur fractures. Methods Adults with AO/OTA 33 distal femur fractures treated with a retrograde ultra-high molecular weight polyethylene (UHMWPE) inlay-design nail (RFNA; DePuy Synthes) or a non-inlay design nail (T2 SCN; Stryker) between January 2015 and June 2025 at a single Level I academic trauma center with a minimum follow-up of 3 months were retrospectively reviewed. The primary outcome was distal interlocking screw backout. Secondary outcomes included time to backout diagnosis, backout distance, and rate of symptomatic screw removal. All outcomes were compared between the inlay-design and the non-inlay design cohorts. Results A total of 134 patients were included: 76 in the inlay cohort and 58 in the non-inlay cohort. The inlay cohort demonstrated a significantly lower rate of distal interlocking screw backout compared to the non-inlay cohort (5.3% vs. 19.0%; RR 0.28, 95% CI 0.09–0.83; p = 0.02), corresponding to a 72.2% relative risk reduction. Time to backout diagnosis and backout distance did not differ significantly between designs. The rate of symptomatic screw removal was significantly lower in the inlay cohort (1.3% vs. 10.3%; p = 0.04). The distal transverse screw was the most common screw with backout in both cohorts. Conclusion The ultra-high molecular weight polyethylene (UHMWPE) inlay at the distal interlocking interface of a retrograde femoral nail was associated with significantly lower rates of distal interlocking screw backout and symptomatic screw removal. When backout did occur, polyethylene inlay did not impact time to diagnosis and backout distance.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- InSafeLock endopin versus conventional distal locking screws for femoral shaft fractures: A comparative laboratory biomechanical study.Medicine · 2026
- Retrograde Intramedullary Nailing Versus Locking Plate Fixation in Extra-Articular Distal Femur Fractures: A Prospective Study.Journal of orthopaedic case reports · 2026
- Retrospective Cohort Study Comparing Rates of Symptomatic Implants Requiring Removal between Standard versus Low-Profile Tibial Nail Interlocking Screws.Journal of long-term effects of medical implants · 2026
- Polyethylene Exchange During Retrograde Intramedullary Nailing in the Treatment of Periprosthetic Distal Femur Fractures: A Registry Pilot Analysis.Journal of the American Academy of Orthopaedic Surgeons. Global research & reviews · 2026
- Plate Versus Nail Fixation in Periprosthetic Distal Femur Fractures: An Updated Systematic Review and Meta-Analysis.HSS journal : the musculoskeletal journal of Hospital for Special Surgery · 2026
- Comparative efficacy and safety of locking intramedullary nails versus locking plates for displaced proximal humeral fractures : a meta-analysis and trial sequential analysis of randomized controlled trial.Bone & joint open · 2026