From the paper's conclusion- Combining supercritical CO₂-processed allograft with local autograft, together with thorough distal decortication of the LIV and LIV-1 laminae, was associated with a significantly lower rate of radiological PS loosening. This strategy may limit micromotion at the caudal end of long constructs in AIS.
Abstract
PURPOSE: Distal radiolucent halos around the lowest instrumented vertebra (LIV) screws represent a radiographic indicator of micromotion and potential distal non-union after posterior spinal fusion (PSF) in Adolescent Idiopathic Scoliosis (AIS). This study aimed to compare the incidence of radiological distal pedicle screw (PS) loosening between constructs using local autograft alone and those supplemented with supercritical CO₂-processed allograft. METHODS: A retrospective analysis was conducted on 360 AIS patients who underwent non-selective PSF between January 2017 and June 2023. Two groups were compared: autograft alone (n = 180) and autograft combined with supercritical CO₂-processed allograft (n = 180). All surgeries were performed by the same surgical team following a standardized technique, including systematic decortication of the distal laminae. Radiological evaluation included Cobb angle measurements, sagittal alignment, and assessment of distal halo formation. Minimum follow-up was 24 months. RESULTS: Groups were comparable regarding age, follow-up duration, preoperative deformity magnitude and correction rates. The incidence of PS loosening was 6.4% in the entire cohort, only located at LIV, and LIV and LIV-1, and was significantly reduced in group 2 (2.8% vs. 10%, p = 0.001). All halos appeared progressively and were not visible before 1 year follow-up. In Group 1, loosening led to 2 unplanned revisions and 5 cases of LIV screw fracture, while no complication was reported in group 2. CONCLUSION: Combining supercritical CO₂-processed allograft with local autograft, together with thorough distal decortication of the LIV and LIV-1 laminae, was associated with a significantly lower rate of radiological PS loosening. This strategy may limit micromotion at the caudal end of long constructs in AIS.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Novel Titanium End-Disc-Assisted Allograft Preparation System for Anterior Cervical Corpectomy and Fusion: Development and Preliminary Biomechanical Evaluation.Bioengineering (Basel, Switzerland) · 2026
- Decellularization of Cartilage Xenograft with Supercritical CO2.Tissue engineering. Part C, Methods · 2026
- Radiographic S1 Pedicle Screw Loosening After Lumbosacral Fusion for Degenerative Disease: A Single-Institution Cohort Study.International journal of spine surgery · 2026
- Radiologic Outcomes Following All-Pedicle Screw Selective Thoracic Fusion in Adolescent Idiopathic Scoliosis Patients With Lenke Type 1 and 2 Curves: A Retrospective Cohort Study With Minimum Five-Year Follow-Up.Clinical spine surgery · 2026
- Supercritical Solution Impregnation: A Strategy to Prevent Prosthetic Infections.Global challenges (Hoboken, NJ) · 2026
- A hydroxyapatite-based synthetic bone graft reduces intervertebral motion at 12 months, as measured by CT-RSA, in a porcine model of ACDF.Brain & spine · 2026