Mitigating radiation in robotic-assisted sacropelvic screw placement using 3D magnetic resonance imaging.
Giuseppe Loggia, Fedan Avrumova, Marco D Burkhard, Michael J Kelly, Franziska C S Altorfer, Joseph Iii C Babrowicz, Allison S Lowe, Jiaqi Zhu,
Department of Spine Surgery, Hospital for Special Surgery, New York, USA. giuseppe.loggia@gmx.ch. · Department of Spine Surgery, Hospital for Special Surgery, New York, USA.
Key points
From the paper's conclusion- This first cadaveric validation of 3D MRI-guided RA sacropelvic fixation demonstrates the feasibility of radiation-free preoperative imaging and robotic registration for precise trajectory execution.
Abstract
OBJECTIVE: To evaluate the feasibility and accuracy of robotic-assisted (RA) sacropelvic screw placement (SPSP) using three-dimensional magnetic resonance imaging (3D MRI) for preoperative planning and robotic registration. SPSP is a critical component of spinal fixation but is subject to trajectory deviations, and radiation exposure with fluoroscopic or computed tomography (CT)-based navigation. CT-like 3D MRI-based navigation provides radiation-free preoperative imaging, but its integration with RA systems remains unexplored in SPSP. METHODS: Eight human cadavers underwent RA SPSP using MRI-based preoperative planning, including the placement of S1 pedicle screws, S1-alar-iliac (AI) screws, and S2-AI screws bilaterally. Accuracy was measured as deviation between planned vs. achieved trajectories by postoperative CT analysis. This was quantified through direct measurements and subsequently categorized using the Gertzbein-Robbins Scale (GRS). RESULTS: A total of 48 screws were placed using 3D MRI-based RA navigation. Postoperative CT confirmed that 46 screws (95.8%) were graded as GRS Grade A. Among the S1 pedicle screws (n = 16), the median deviation from the planned trajectory was 0.5 mm (IQR 0.3-0.8) in the axial plane and 0.8 mm (IQR 0.5-0.9) in the sagittal plane. For S1AI and S2AI screws (n = 30), the median deviation at the entry point was 0.7 mm (IQR 0.3-1.2), while the median axial deviation from the medial SI joint border measured 0.9 mm (IQR 0.6-1.7). CONCLUSION: This first cadaveric validation of 3D MRI-guided RA sacropelvic fixation demonstrates the feasibility of radiation-free preoperative imaging and robotic registration for precise trajectory execution.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Augmented reality-enabled image-guided surgical navigation in minimally invasive spine surgery: application beyond screw placement in prone lateral transpsoas interbody fusion-a cadaveric surgical technique study.Journal of spine surgery (Hong Kong) · 2026
- The accuracy of navigated vs. robot-assisted pedicle screw placement in spine surgery: a retrospective single-centre comparative study.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026
- Mind the gap: discrepancies between planned and achieved screw trajectories in 3D-navigated spine surgery.Journal of neurosurgery. Spine · 2026
- A fiducial-based framework for precise MRI-guided stereotaxic targeting in nonhuman primates.bioRxiv : the preprint server for biology · 2026
- Metal artifact reduction for 3 T MRI-only prostate radiotherapy in patients with hip prostheses: impact on target definition, synthetic CT generation, dose calculation, and fiducial marker identification.Radiation oncology (London, England) · 2026
- Comparative evaluation of CT-to-Fluoroscopy and Scan-and-Plan registration techniques in robot-assisted pedicle screw placement: a preliminary cadaveric faesibility study.Journal of robotic surgery · 2026