Right- versus left-sided double-lumen tubes and hypoxemia during anesthesia in patients undergoing unilateral surgery for left-sided lung tumors.
Taishi Saito, Kyosuke Takahashi, Yusuke Iizuka, Yuji Otsuka, Shigehiko Uchino, Masamitsu Sanui
Department of Anesthesiology and Critical Care Medicine, Jichi Medical University Saitama Medical Center, 1-847, Amanuma-Cho, Omiya-Ku, Saitama, Saitama, 330-8503, Japan. · Department of Anesthesiology, Institute of Science Tokyo Hospital, 1-5-45, Yushima, Bunkyo-Ku, Tokyo, 113-8519, Japan.
Key points
From the paper's conclusion- We found no clear evidence that right-sided DLT use was associated with a higher incidence of hypoxemia during anesthesia than left-sided DLT use. However, equivalence between the two devices was not established, and further studies are needed to determine whether clinically important differences in hypoxemia risk exist.
Abstract
PURPOSE: Right-sided double-lumen endobronchial tubes (DLTs) are often avoided because of technical difficulties and concerns about respiratory complications, although evidence that they increase hypoxemia during anesthesia remains limited and inconsistent. We evaluated the association between DLT side and hypoxemia during anesthesia in patients undergoing unilateral surgery for left-sided lung tumors. METHODS: This single-center retrospective cohort study included adult patients undergoing unilateral surgery for left-sided lung tumors between October 2008 and May 2023. The primary outcome was hypoxemia during anesthesia, defined as SpO2 ≤ 90% for at least 3 consecutive min during the anesthetic period. Propensity score overlap weighting was used to adjust for measured differences between patients receiving right-sided and left-sided DLTs. Odds ratios (ORs) and absolute risk differences (RDs) were estimated. RESULTS: Among 1,280 patients, 842 received right-sided DLTs and 438 received left-sided DLTs. After overlap weighting, measured covariates were well balanced. The incidence of hypoxemia during anesthesia was 20.0% with right-sided DLTs and 18.5% with left-sided DLTs (OR, 1.10; 95% confidence interval [CI], 0.68-1.79; P = 0.70). The RD was 1.51 percentage points (95% CI - 3.86-6.87). No clear between-group differences were observed in exploratory secondary respiratory outcomes. CONCLUSION: We found no clear evidence that right-sided DLT use was associated with a higher incidence of hypoxemia during anesthesia than left-sided DLT use. However, equivalence between the two devices was not established, and further studies are needed to determine whether clinically important differences in hypoxemia risk exist.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Right upper lobectomy via selective right upper lobe isolation using a left-sided double-lumen tube placed in the right bronchus intermedius: a case report.BMC surgery · 2026
- Video laryngoscope-guided double-lumen tube tracheal intubation in the left-lateral position for thoracoscopic surgery: an open-label randomized non-inferiority trial.American journal of translational research · 2026
- Video double-lumen tube intubation in a modified lateral position for unilateral video-assisted thoracoscopic surgery: a randomized controlled trial.Canadian journal of anaesthesia = Journal canadien d'anesthesie · 2026
- Research progress in the application of double-lumen endobronchial tubes and bronchial blockers in thoracic surgery.Frontiers in medicine · 2026
- Fiberoptic Bronchoscopy-Guided Bronchial Blocker Placement in Lateral Versus Supine Positions in Video-Assisted Thoracic Surgery: A Comparative Study.Journal of visualized experiments : JoVE · 2026
- Association of Graft Laterality With Outcomes After Single Lung Transplantation.The Journal of surgical research · 2026