Canadian journal of anaesthesia = Journal canadien d'anesthesie

Video double-lumen tube intubation in a modified lateral position for unilateral video-assisted thoracoscopic surgery: a randomized controlled trial.

Chenrong Zhang, Bohao Liu, Shan Gao, Zexu Gao, Zhiying Wang, Jinteng Feng, Zihuan Wei, Lei Ma,

Department of Thoracic Surgery, the First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, China. · Department of Anesthesiology, the First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, China.

Randomised · n=31

Key points

From the paper's conclusion
  • In patients undergoing unilateral VATS, VDLT intubation in a modified lateral position shortened IRCT. In exploratory analyses, several secondary outcomes favoured this approach. Intubation in a modified lateral position may be a feasible alternative to conventional supine position intubation in these patients.

Abstract

PURPOSE: We aimed to evaluate and report a protocol for video double-lumen tube (VDLT) intubation in a modified lateral position and evaluate whether it shortens in-room to cut time (IRCT; defined as the time from patient entry to incision) compared with conventional supine intubation in patients undergoing elective unilateral video-assisted thoracoscopic surgery (VATS). METHODS: We conducted a single-centre, prospective, parallel-group, randomized controlled superiority trial at a tertiary university hospital in Xi'an, China. We enrolled adults aged 18-75 yr (American Society of Anesthesiologists Physical Status I-III) scheduled for elective unilateral VATS requiring VDLT intubation; exclusions included body mass index > 30 kg·m-2, mouth opening < 3 cm, Mallampati class 3-4, or anticipated difficult airway. Participants were randomized 1:1 to modified-lateral-position (Group L) or supine-position (Group S) VDLT intubation using a computer-generated sequence with sealed-envelope allocation concealment. Operators were unblinded; nonoperator staff collecting postoperative data and the outcome analyst were blinded to allocation. The primary outcome was IRCT. RESULTS: Sixty-two patients were randomized (Group L, N = 31; Group S, N = 31), and all were analyzed for the primary outcome. Mean (standard deviation [SD]) IRCT was shorter in Group L (18.1 [2.0] min) than in Group S (31.1 [3.3] min), with a mean difference (L-S) of -13.0 min (95% confidence interval [CI], -14.4 to -11.6; P < 0.001). Intubation time was similar (mean [SD], 103 [15] sec vs 97 [15] sec; P = 0.10). Video double-lumen tube malpositioning occurred in 1/31 (3%) cases in Group L vs 15/31 (48%) cases in Group S (relative risk [RR], 0.067; 95% CI, 0.009 to 0.474; P < 0.001). Sore throat within 48 h occurred in 9/31 (29%) patients in Group L vs 18/31 (58%) patients in Group S (RR, 0.50; 95% CI, 0.27 to 0.94; P = 0.02). CONCLUSIONS: In patients undergoing unilateral VATS, VDLT intubation in a modified lateral position shortened IRCT. In exploratory analyses, several secondary outcomes favoured this approach. Intubation in a modified lateral position may be a feasible alternative to conventional supine position intubation in these patients. TRIAL REGISTRATION: ChiCTR.org.cn ( ChiCTR2500112254 ); first posted 21 October 2025.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers