Reliability analysis and clinical validation of smart portable ECG devices for home patient cardiac care
Kunvar Kant Patel, Basant Kumar
Motilal Nehru National Institute of Technology
Key points
From the paper's conclusion- The ICC is evaluated with a high value of 0.9957 (99.57%), demonstrating the excellent reliability of Spandan ECG devices.
Abstract
Abstract This research paper presents a detailed reliability analysis and validation of a smartphone-based Electrocardiogram (ECG) acquisition device (Spandan) for prior-cardiac disorder detection for home patients. Numerous IoT-based wearable medical devices for continuous cardiovascular signal monitoring are available; however, conducting validation and reliability analyses of these medical devices is crucial to ensure their effectiveness. The study includes 28 normal and abnormal participants for the investigation of the Spandan ECG device. It aims to validate and assess the reliability of the Spandan ECG device with respect to the RMS Vesta 301i ECG device (standard 12-lead ECG device). So, this study compares the time interval of the ECG parameters of the Spandan ECG device with the RMS Vesta 301i ECG device. The statistical analysis reveals that the Spandan ECG device achieves an overall accuracy of 95.3% with respect to the RMS Vesta 301i ECG device. The investigation of the reliability of the Spandan devices is assessed using Bland-Altman limits of agreement, Intra-class correlation coefficient (ICC), Paired t-tests, Repeatability test, and Pearson coefficient. The ICC is evaluated with a high value of 0.9957 (99.57%), demonstrating the excellent reliability of Spandan ECG devices. The obtained p-value is 0.0001, which signifies a substantial degree of agreement between Spandan and the RMS Vesta 301i ECG device.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Validation of Commercial Wearables for Driver Monitoring: Assessing Heart Rate Accuracy and Reliability for Early Detection of Sudden IllnessesApplied Sciences · 2026
- Performance evaluation of smartwatches: Can they match clinical standards for ECG analysis?Biomedical Signal Processing and Control · 2025
- Seizure detection using wearable electrocardiogram connected to a smartphone: a phase 3 clinical validation studyEBioMedicine · 2025
- Wearable 12-lead electrocardiogram for detecting acute myocardial ischemia: a prospective diagnostic accuracy studyEuropean Heart Journal · 2026
- Multi-Tier Validation of a Single-Lead Wearable ECG Signal-Processing Pipeline: Clinical Comparison and Algorithmic Benchmarking on Public Expert-Annotated Databases.Sensors (Basel, Switzerland) · 2026
- Inter-Lead RRI Agreement Between Lead I and Lead II Across Diagnostic ECG Categories: Pilot Evidence for Wearable HRV MonitoringApplied Sciences · 2026