Ergonomic impact of closed-console (Da Vinci Xi) versus open-console (Hugo RAS) robotic systems: an ex vivo randomized crossover controlled trial.
R Sagar Rathod, Hemanga K Bhattacharjee, Mohit Kaushik, Om Prakash Prajapati, Manjunath Pol, Washim F Khan, Ashwani K Mishra, Vinay Gupta,
Department of Surgical Disciplines, All India Institute of Medical Sciences, New Delhi, India. · Department of Surgical Disciplines, All India Institute of Medical Sciences, New Delhi, India. dr_hkb75@yahoo.com.
Key points
From the paper's conclusion- Both robotic systems have negative ocular impact, although more with open console. Musculoskeletal discomfort was more on closed console. These findings emphasize the need for ocular and ergonomic training and console design improvements.
Abstract
BACKGROUND: Robotic technology, based on either open- or closed-console systems, has improved precision, visualization, and ergonomics for surgeons. However, its effects on surgeons' visual health and ocular function have not been studied. METHODS: A randomized crossover trial was conducted among 20 stereo-enabled surgery residents. They were randomly allocated into closed-console (DaVinci Surgical system) or open-console (HugoTMRAS) groups. Participants did identical simulated tasks for 90 min. Visual strain was assessed subjectively using visual fatigue questionnaire and objectively through near point of accommodation (NPA) and near point of convergence (NPC) using RAF ruler test, stereoacuity using Netherlands Organisation for Applied Scientific Research (TNO) stereopsis test, tear production using Schirmer's test, and tear film stability using Tear Break-Up Time (TBUT). Musculoskeletal strain was measured using SAGES body discomfort and NORDIC musculoskeletal questionnaire (NMSQ). RESULTS: Both groups had comparable demographics and ophthalmic parameters at baseline. After simulated task, open-console group had significant worsening in tearing (p = 0.042), while close console group had significant deterioration in neck stiffness (p=0.018), neck discomfort (p = 0.046), and upper back discomfort (p = 0.019). Within-platform analysis showed post-task increase in pressure around eyes (p = 0.011), dry eyes (p = 0.008), heaviness of eyelids (p = 0.007), headache (p = 0.025), eye pain (p = 0.024), worsened NPC (p = 0.014), and declined TBUT (right: p = 0.044; left: p = 0.022) in open console. Closed-console group had increased pressure around eyes (p = 0.015), dry eyes (p = 0.013), heaviness of eyelids (p = 0.042); worsened NPC (p = 0.009), and declined left-eye TBUT (p = 0.010). CONCLUSION: Both robotic systems have negative ocular impact, although more with open console. Musculoskeletal discomfort was more on closed console. These findings emphasize the need for ocular and ergonomic training and console design improvements.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Ergonomic impact of open- versus closed-console robotic systems on surgeon fatigue and musculoskeletal strain: A prospective, experimental, wet-lab comparative study.Journal of minimal access surgery · 2026
- Surgical team ergonomics during robotic versus conventional laparoscopic surgery: a prospective observational study.Journal of robotic surgery · 2026
- Comparative evaluation of robotic surgical systems in oculoplastic surgery: A study of Da Vinci versus medtronic hugo RAS in standardized eyelid incisions.Indian journal of ophthalmology · 2026
- Surgeons' Perception Questionnaire on Robotics (SPQR): development and preliminary validation of a surgeon-reported instrument for robotic surgery.Journal of robotic surgery · 2026
- Comparative Ergonomic Assessment of Microscopic, Endoscopic, and RobOtol®-Assisted Ear Surgery: A Prospective Pilot Study.Journal of clinical medicine · 2026
- Comparative operative performance of three robotic platforms in benign gynecologic surgery: a single-surgeon retrospective cohort study.Journal of robotic surgery · 2026