Analysis of sodium self-inhibition of the epithelial sodium channel (ENaC) using classical and medium-throughput automated two-electrode voltage-clamp recordings.
Karen Lizet Luján López, Nadja Furtwängler, Carol Merlin Frank, Mike Althaus, Oliver Rauh
Institute for Functional Gene Analytics, Bonn-Rhein-Sieg University of Applied Sciences, Von-Liebig-Str. 20, Rheinbach, 53359, Germany. · Institute for Functional Gene Analytics, Bonn-Rhein-Sieg University of Applied Sciences, Von-Liebig-Str. 20, Rheinbach, 53359, Germany. mike.althaus@h-brs.de.
Key points
From the paper's conclusion- Here, we improved and evaluated experimental strategies and analytical methods for robust quantification of ENaC SSI in manual and automated TEVC systems: (1) The determination of SSI from extrapolation of transient current recordings in response to a jump in the extracellular Na+ concentration; (2) the estimation of SSI by comparison of steady-state currents before and after chemical modification
Abstract
The epithelial sodium channel (ENaC) is a key regulator of electrolyte homeostasis and blood pressure. A characteristic ENaC feature is sodium self-inhibition (SSI), a rapid autoregulatory mechanism in which extracellular Na+ ions allosterically bind ENaC and facilitate transition into a low open probability state. Although SSI is an important functional parameter for assessing ENaC activity and gating, its quantification has traditionally relied on manual two-electrode voltage-clamp (TEVC) recordings with limited scalability and throughput. Here, we improved and evaluated experimental strategies and analytical methods for robust quantification of ENaC SSI in manual and automated TEVC systems: (1) The determination of SSI from extrapolation of transient current recordings in response to a jump in the extracellular Na+ concentration; (2) the estimation of SSI by comparison of steady-state currents before and after chemical modification of a βS520C-ENaC mutant with MTSET; and (3) quantification of SSI from the analysis of steady-state current-voltage relationships recorded at different extracellular Na+ concentrations. The latter procedure is the most reliable for SSI quantification in perfusion rate-limited automated TEVC systems. These methods can expand the capabilities of automated electrophysiology and support medium- to high-throughput investigation of autoregulatory mechanisms in ENaC variants and the discovery of novel ENaC modulators.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Acid-sensing ion channel 2a assembles with epithelial Na+ channel β and γ subunits to form mechanosensitive ion channelsJournal of Biological Chemistry · 2026
- Evolution of electrochemical biosensors for urinary ENaC detection: from biomarker discovery to point-of-care monitoring of renal sodium adaptation.Chemical communications (Cambridge, England) · 2026
- A nanoscale gap junction–perinexus nanodomain governs balance of ephaptic and gap-junctional activation in excitable cell pairsProceedings of the National Academy of Sciences · 2026
- Ion-selective electrodes for in vivo applications in animal models: from single-time measurement to long-term monitoring.Science bulletin · 2026
- Protocol for assessing endolysosomal chloride channel function in mammalian cells using endolysosomal patch-clamp technique.STAR protocols · 2026
- A reproducible event-driven analytical framework for ECG-derived skin sympathetic nerve activity analysis: towards afferent signal processing for closed-loop neuromodulation.Frontiers in bioengineering and biotechnology · 2026