Mechanical stresses on the retina induced by intravitreal injections in an artificial model of the vitreous chamber
Laura Panebianco, Alessandro Stocchino
Hong Kong Polytechnic University
Key points
From the paper's conclusion- We computed the normal and shear stress exerted by the fluid on the retina.
Abstract
BACKGROUND: The use of artificial models of the eye globe has been proposed as an alternative to human and animal samples for studying drug delivery using intravitreal injections (IVIs). The induced fluid dynamics processes are important in terms of the stress generated at the level of the retina and implications on drugs diffusion. METHODS: The experiments were performed on an in-scale, 3D printed model of the vitreous chamber with a realistic shape. We simulated the vitreous humor as a Newtonian fluid with a mixture of diethyl phthalate (DEP) and ethanol. A 0.1 mL volume of the same fluid was injected with fixed angle and direction, for a total of 224 experiments, varying the needle size (from 25G to 32G), needle length, fluid viscosity, and operator. We measured the velocity field on a 2D plane containing the injection needles with the Particle Image Velocimetry (PIV) technique. We computed the normal and shear stress exerted by the fluid on the retina. RESULTS: The PIV measurements show a jet-shaped flow following the injection, extending from the injection site to the retina. After the impact, a highly rotational recirculating flow develops from the impinging point upwards along the retina towards the lens, with maximum velocities of about 0.1 - 0.3 m/s. Values of maximum normal stress are in the range of 15-100 Pa, mostly due to pressure peaks, with higher values for 31G and 32G needles. The maximum shear stress is estimated to be on the order of 1 Pa. A statistically significant variability is observed in the inter- and intra-operator comparison. CONCLUSIONS: The observed stresses are comparable with previous numerical and experimental studies investigating the effects of head and eye movements on retinal detachment. However, the measured values are lower than those estimated for the adhesion force of the retina. These results provide complementary information for the development of general guidelines for IVIs administration, specifically regarding the choice of the injection needle.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Physical Parameters Influencing the Rate of Subretinal Injection: A Microfluidic Analysis.Translational vision science & technology · 2026
- In vitro analysis of triamcinolone acetonide dissolution and diffusion in vitreous substitutesEuropean Journal of Pharmaceutical Sciences · 2026
- Performance characterization of syringes used for intravitreal injections: dosing accuracy, particulate contamination, and residual volume.International journal of retina and vitreous · 2026
- Swinging vs Flicking: Assessing Safer Removal Techniques for Air Bubbles in Intravitreal Injections.Journal of vitreoretinal diseases · 2026
- Shear Stress and Pressure Homeostasis in the Eye's Aqueous Outflow Pathway.Journal of biomechanical engineering · 2026
- Imaging Approaches to Quantifying the Biomechanical Properties of the Human Vitreous In Vivo: A Review.Bioengineering (Basel, Switzerland) · 2026