Supraglottic airway vs. endotracheal tube for sinonasal surgery: a systematic review and meta-analysis.
Alfred Cuddeford, Zahra Mubaarak, Badriya Yussuf, Suliman Ali, Avenie Mavadia, Chuanyu Gao, Yadsan Devabalan, Rahim Dhanani,
Department of Otolaryngology, Northampton General Hospital, Northampton, United Kingdom. alf.cuddeford@nhs.net. · Department of Otolaryngology, Northampton General Hospital, Northampton, United Kingdom.
Key points
From the paper's conclusion- The historical concern that SGAs offer inferior airway protection during ESS is not supported by current comparative evidence. In appropriately selected, low-aspiration-risk patients, SGAs represent a safe alternative to ETs. Given the heterogeneous evidence base, findings should assist rather than replace clinical judgment, with device selection guided by individual patient and procedural factors.
Abstract
PURPOSE: This systematic review evaluates the relative safety and side-effect profiles of endotracheal tubes (ETs) and supraglottic airway devices (SGAs) for airway management in endoscopic sinus surgery (ESS). METHODS: A search of MEDLINE, Embase and the Cochrane Library was conducted in April 2025. Random-effects meta-analysis was performed for outcomes reported by three or more studies with comparable methodology; remaining outcomes were synthesised narratively. Primary outcomes were aspiration events, airway contamination and adverse post-operative symptoms (cough, sore throat, hoarseness, nausea and vomiting); secondary outcomes were operative time and estimated blood loss. Nine studies (714 patients, 1995-2024) were eligible. RESULTS: Aspiration was rare (one asymptomatic ET case). Pooled analysis demonstrated a significant reduction in airway contamination with SGA use (RR 0.27, 95% CI 0.15-0.47, I²=0%). Device contamination was common in both (SGAs 0-86%, ETs 53-77%) but of limited clinical consequence. Pooled analysis also demonstrated a significant reduction in post-operative day 0 cough with SGA use (RR 0.39, 95% CI 0.23-0.68, I²=0%), whereas day 0 sore throat showed no significant difference (RR 0.65, 95% CI 0.24-1.74, I²=68.7%). Trends toward reduced hoarse voice, blood loss and operative time favoured SGAs but were not significant. CONCLUSION: The historical concern that SGAs offer inferior airway protection during ESS is not supported by current comparative evidence. In appropriately selected, low-aspiration-risk patients, SGAs represent a safe alternative to ETs. Given the heterogeneous evidence base, findings should assist rather than replace clinical judgment, with device selection guided by individual patient and procedural factors.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A narrative review of airway changes after prolonged use of supraglottic airway devices: Molecular mechanisms, pathophysiology, and preventive strategies.Journal of anaesthesiology, clinical pharmacology · 2026
- Tulip-shaped vs. classic gel supraglottic airway device on hypopharyngeal secretion pH: a randomised clinical trial.Open medicine (Warsaw, Poland) · 2026
- Our Experience with the Use of 3rd-Generation Video LMA in Patients Undergoing Head and Neck SurgeryMedicina · 2026
- Clinical performance of i-gel and classic laryngeal mask airway in different head positions in patients aged ≥75 years: A prospective randomized study.The Journal of international medical research · 2026
- I-gelTM Plus implements higher oropharyngeal leak pressure in the lateral decubitus position than original i-gelTM: a prospective randomized controlled trial.Anaesthesia, critical care & pain medicine · 2026
- Association between supraglottic airway device use and respiratory adverse events during airway management in children with airway hyperresponsiveness: a report from the Japan Paediatric Difficult Airway in Anaesthesia (J-PEDIA) registry.British journal of anaesthesia · 2026