Archives of orthopaedic and trauma surgery

Comparison of mold-based, handmade, and prefabricated articulating cement spacers in two-stage revision total knee arthroplasty for periprosthetic joint infection: a retrospective comparative study.

Tahsin Aydın, Yakup Kahve, Olgun Bingöl, Erman Ceyhan, Bülent Özkurt, Özdamar Fuad Öken

Department of Orthopaedics and Traumatology, Ankara Bilkent City Hospital, Ankara, Turkey. drtahsinaydin@gmail.com. · Department of Orthopaedics and Traumatology, Ankara Bilkent City Hospital, Ankara, Turkey.

Observational · n=75

Key points

From the paper's conclusion
  • Articulating antibiotic-loaded cement spacers may be prepared using handmade, mold-based, or prefabricated techniques; however, high-quality comparative evidence is limited, and the 2025 International Consensus Meeting on Musculoskeletal Infection identified this as a knowledge gap.

Abstract

INTRODUCTION: Periprosthetic joint infection (PJI) following total knee arthroplasty (TKA) is a devastating complication most commonly managed with two-stage revision. Articulating antibiotic-loaded cement spacers may be prepared using handmade, mold-based, or prefabricated techniques; however, high-quality comparative evidence is limited, and the 2025 International Consensus Meeting on Musculoskeletal Infection identified this as a knowledge gap. We aimed to compare a mold-based technique that uses a dedicated reusable sterile mold prepared from previously explanted components, used solely as a back-table molding tool and never reimplanted into the joint, with conventional handmade and commercially available prefabricated spacers. MATERIALS AND METHODS: We retrospectively analyzed 75 patients undergoing two-stage revision TKA for PJI (June 2019-August 2025), grouped by spacer technique: mold-based (n = 18), handmade (n = 36), and prefabricated (n = 21). PJI was diagnosed per the 2018 ICM criteria. The primary outcome was final range of motion (ROM). Secondary outcomes were KSS, WOMAC, Oxford Knee Score, infection eradication, complications, and per-patient cost. Groups were compared using Kruskal-Wallis and chi-square/Fisher tests with Bonferroni post-hoc correction. RESULTS: Baseline demographics and infection markers were comparable across groups. Final ROM tended to be highest in the mold group (105.8° ± 13.6°) compared with the handmade (99.3° ± 11.7°) and prefabricated (103.1° ± 11.1°) groups, without reaching statistical significance (p = 0.227). No significant differences were observed in KSS-Knee, KSS-Function, WOMAC, or Oxford scores. Infection eradication rates were 94.4% (mold), 94.4% (handmade), and 90.5% (prefabricated) (p = 0.826). Spacer-related complications occurred in 11.1%, 30.6%, and 14.3%, respectively (p = 0.168), with all spacer fractures (n = 4) confined to the handmade group. In our institutional setting, the direct material cost of the mold-based construct was approximately 46% of the prefabricated spacer construct cost (approximately 54% lower). CONCLUSIONS: The mold-based technique using explanted components yielded clinical outcomes that did not differ significantly from those of handmade and prefabricated spacers, with a lower direct material cost than the prefabricated spacer, and may represent a practical lower-cost alternative to prefabricated spacers in resource-limited settings. Larger prospective studies are needed to confirm these findings. LEVEL OF EVIDENCE: III-retrospective comparative study.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Comparison of mold-based, handmade, and prefabricated articulating cement spacers in two-stage revision total knee arthroplasty for periprosthetic joint infection: a retrospective comparative study — Science Skim