Proposed quantitative workflow for localization and characterization of parathyroid adenoma using dual-energy 4D CT.
Om Biju Panta, Francesca Rigiroli, Ongden Tamang, Suraj Sharma, Alexander Brook, Yu-Ming Chang, Olga R Brook
Department of Radiology, Beth Israel Deaconess Medical Center, Boston, MA, USA. · Department of Radiology, Lahey Hospital and Medical Center, Burlington, MA, USA.
Key points
From the paper's conclusion- Workflow strategy using a combination of cutoff and within-patient pairwise analysis on non-contrast, 55 keV arterial and venous-phase DECT achieved high sensitivity for detection and characterization of parathyroid adenoma.
Abstract
OBJECTIVES: To construct an imaging workflow using 4D DECT for the localization and characterization of parathyroid adenomas. MATERIALS AND METHODS: This IRB-approved, HIPAA-compliant retrospective study included patients who underwent DECT of the neck between June 1, 2023, and May 30, 2024, with pathology-confirmed parathyroid adenomas. A research fellow with 12 years of clinical radiology experience obtained attenuation of parathyroid adenoma, thyroid, lymph node on non-contrast, virtual non-contrast, 70 keV and 55 keV dual-energy CT, and iodine maps for arterial and venous phases. Two additional clinical fellows repeated the measurements to evaluate the interobserver variability. Conspicuity of the lesion was calculated by contrast-to-noise ratio of the parathyroid relative to the thyroid gland. Statistical analysis employed the Friedman test, Mann-Whitney U tests, one-way ANOVA, and ROC curves. RESULTS: The study included 40 patients (31 females; mean age 57.7 ± 13.4 years) with 55 confirmed parathyroid adenomas. The highest contrast-to-noise ratio was seen in arterial-phase iodine concentration (5.7; IQR: 3.5-9.6). Non-contrast (AUC: 0.91), using cutoff value < 54 HU, achieved 81.8 (71.8-91.8)% sensitivity and 95 (88.6-100)% specificity for differentiation of parathyroid from thyroid, and 55 keV arterial (AUC: 0.97), using cutoff value of > 150 HU on 55 keV arterial phase achieved 94.5 (88.4-100) % sensitivity and 90 (80.8-99.2) % specificity for differentiation of parathyroid from lymph node. Combining cutoff values and within-patient pairwise comparison between the lesion, thyroid, and lymph node increased sensitivity to 98% for the characterization of parathyroid adenoma. CONCLUSION: Workflow strategy using a combination of cutoff and within-patient pairwise analysis on non-contrast, 55 keV arterial and venous-phase DECT achieved high sensitivity for detection and characterization of parathyroid adenoma. KEY POINTS: Question What is a systematic imaging approach for image review and measurement for identification and characterization of parathyroid adenoma on multiphasic dual-energy CT? Findings A systematic workflow combining arterial-phase iodine mapping, non-contrast, 55 keV arterial threshold cutoffs, and within-patient pairwise analysis achieved 98.2% sensitivity for parathyroid adenoma. Clinical relevance The proposed quantitative workflow for the identification and characterization of parathyroid adenoma in multiphasic dual-energy CT may enhance preoperative localization of suspected parathyroid adenomas. Its effects on surgical approach, procedure time, cost, and morbidity require prospective evaluation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Diagnostic performance of dual-phase photon-counting detector for localization of parathyroid adenomas after inconclusive first-line imaging.Insights into imaging · 2026
- Contrast-Enhanced Dual-Energy CT for Differentiating Paragangliomas From Other Neck Masses: A Quantitative Diagnostic Approach.Head & neck · 2026
- The Diagnostic Utility of Multiphase-CT (4D CT) in Localising Parathyroid Adenomas Following Negative or Discordant 99mTc-Sestamibi SPECT/CT and Ultrasound Imaging.The British journal of radiology · 2026
- Visual Parathyroid Identification in Thyroidectomy: A Decision Curve Analysis of Gland Preservation.The Laryngoscope · 2026
- Dual-energy computed tomography as an alternative to computed tomography perfusion for assessment of pancreatic ductal adenocarcinoma.Journal of gastrointestinal oncology · 2026
- Photon-Counting Detector 4D CT for Preoperative Localization in Primary Hyperparathyroidism.AJNR. American journal of neuroradiology · 2026